GE Xiao-lan, XU Xiao-jing, ZHANG Jie. Wear behaviour of submicrometer SiCP reinforced Al matrix composite[J]. Acta Materiae Compositae Sinica, 2006, 23(5): 1-6.
Citation: GE Xiao-lan, XU Xiao-jing, ZHANG Jie. Wear behaviour of submicrometer SiCP reinforced Al matrix composite[J]. Acta Materiae Compositae Sinica, 2006, 23(5): 1-6.

Wear behaviour of submicrometer SiCP reinforced Al matrix composite

  • The pressure properties , Vickers hardness and sliding wear-resistance of 1. 5~5 vol % SiCP (130 nm) / Al(149~75μm) mat rix composites fabricated by powder metallurgy and hot ext rusion were investigated to research theeffect of submicrometer SiCP dispersed in alumina mat rix on the wear behaviour. The result s show that increase inthe volume f raction of SiCP causes Vickers hardness increasing. It s Vickers hardness is 28. 4 and 33. 3 when thevolume f raction of SiCP (130 nm) is 1. 5~5 vol %. The pressure properties of the material are 170 MPa and 186 MParespectively. Under the higher load , the sliding wear - property increases with increasing the volume f raction ofSiCP ; 1. 5 vol % and 5 vol % SiCP / Al composites have higher sliding wear-behavior than 61520. 4 bronze bearing material and Al. An excellent wear-resistance microst ructure consisting of aluminum mat rix and minute hole and homogeneous dist ribution SiCP is formed in the wear surface of SiCP / Al mat rix composites.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return