Processing math: 36%

吸水性微胶囊/水泥基材料的多尺度界面表征及其自修复效果

师树青, 毛倩瑾, 陈佳艺, 张璐, 王子明, 崔素萍

师树青, 毛倩瑾, 陈佳艺, 等. 吸水性微胶囊/水泥基材料的多尺度界面表征及其自修复效果[J]. 复合材料学报, 2025, 42(3): 1578-1587. DOI: 10.13801/j.cnki.fhclxb.20240626.003
引用本文: 师树青, 毛倩瑾, 陈佳艺, 等. 吸水性微胶囊/水泥基材料的多尺度界面表征及其自修复效果[J]. 复合材料学报, 2025, 42(3): 1578-1587. DOI: 10.13801/j.cnki.fhclxb.20240626.003
SHI Shuqing, MAO Qianjin, CHEN Jiayi, et al. Multiscale interfacial characterization and self-healing effect of water-absorbing microcapsules/cement-based materials[J]. Acta Materiae Compositae Sinica, 2025, 42(3): 1578-1587. DOI: 10.13801/j.cnki.fhclxb.20240626.003
Citation: SHI Shuqing, MAO Qianjin, CHEN Jiayi, et al. Multiscale interfacial characterization and self-healing effect of water-absorbing microcapsules/cement-based materials[J]. Acta Materiae Compositae Sinica, 2025, 42(3): 1578-1587. DOI: 10.13801/j.cnki.fhclxb.20240626.003

吸水性微胶囊/水泥基材料的多尺度界面表征及其自修复效果

基金项目: 国家自然科学基金项目-创新研究群体项目(51621003)
详细信息
    通讯作者:

    毛倩瑾,博士,副教授,硕士生导师,研究方向为混凝土外加剂、自修复混凝土 E-mail: maoqj@bjut.edu.cn

  • 中图分类号: TU599;TB332

Multiscale interfacial characterization and self-healing effect of water-absorbing microcapsules/cement-based materials

Funds: National Natural Science Foundation of China-Innovative Research Group Project (51621003)
  • 摘要:

    针对以海藻酸钙为壳、环氧树脂E-51为核的吸水性微胶囊(SA)与水泥基体界面结合力较弱的问题,利用硅烷偶联剂对SA微胶囊表面进行修饰处理,改善其与水泥基体的界面结合,以提升自修复效果。采用SEM、显微硬度和拉拔试验等分析测试手段分别从微观、介观到宏观尺度分析界面结合情况,并通过砂浆试件损伤修复后的抗压强度、抗水渗透性的恢复率来评价自修复效果。研究结果表明:SA经偶联剂KH792修饰处理后,与水泥基体的界面结合更为紧密,界面处显微硬度提高了159%,界面粘结强度提高了67%;掺加4wt%(水泥质量)SA的砂浆,荷载损伤修复后抗压强度恢复率103%,水压损伤修复后抗渗性恢复率达到118%。硅烷偶联剂表面修饰显著提升了SA与水泥基体的界面结合,水泥基材料自修复效果增强。

     

    Abstract:

    Aiming at the problem of weak interfacial binding force between the absorbent microcapsule (SA) with calcium alginate as shell and epoxy resin E-51 as core and cement matrix, silane coupling agent was used to modify the surface of SA microcapsule to improve its interfacial binding with cement matrix, so as to improve the self-healing effect. By means of SEM, microhardness and drawing test, the interface bonding was analyzed from micro, mesoscopic to macro scale, and the self-healing effect was evaluated by the recovery rate of compressive strength and water permeability resistance of the mortar specimen after damage repair. The results show that the interface bond between SA and cement matrix is closer after modification with coupling agent KH792, the microhardness at the interface is increased by 159%, and the interface bond strength is increased by 67%. For the mortar mixed with 4wt% (cement mass) SA, the compressive strength recovery rate after load damage is 103%, and the seepage resistance recovery rate after water pressure damage is 118%. The surface modification of silane coupling agent significantly improved the interface bonding between SA and cement matrix, and the self-healing effect of cement-based materials was enhanced.

     

  • 超高性能混凝土(UHPC)是一种具有高强度、高韧性、高耐久性的水泥基复合材料,与钢筋具有超高的黏结强度[1-2]。UHPC在重载、大跨、抗震、抗爆和抗冲击等结构中具有广阔的应用前景。与钢筋/普通混凝土结构相同,配筋/UHPC结构中存在钢筋连接接长问题,最简便的钢筋连接接长方式是搭接连接,钢筋/UHPC的高黏结强度可以使钢筋的搭接长度大幅缩短,使UHPC得以用于预制装配式桥梁结构[3-4]和建筑结构[5]中预制构件的连接,仅需较小的搭接长度且钢筋无需弯钩锚固,减少了施工的复杂程度和现场湿作业量。另外,Dagenais等[6]还应用UHPC的高黏结性能加固搭接长度不足的钢筋/混凝土结构,取得了良好效果。

    采用直接拔出锚固试验是较为常用的研究钢筋/UHPC黏结性能的试验方法。Graybeal[7]将直径为12.7 mm、15.9 mm、19.1 mm的钢筋分别锚固75 mm、100 mm、125 mm于UHPC圆柱体中,均发生钢筋拉断破坏而未出现黏结破坏。Swenty等[8]采用直径为12.7 mm的钢筋锚固于边长为150 mm的立方体试块中,采用两种不同配合比的UHPC,分别实现了钢筋的屈服和拉断。Holschemacher等[9]采用直径为12 mm的钢筋锚固在UHPC圆柱体中,测得黏结强度高达60 MPa。Jungwirth等[10]对直径为20 mm和12 mm的钢筋进行锚固试验,黏结强度分别达到38 MPa和66 MPa。Alkaysi等[11]通过锚固试验研究了UHPC的早期龄期(1天、3天、7天)的黏结强度,结果表明在7天龄期时,可以达到75%的最终黏结强度。Graybeal[12]的试验结果表明:影响UHPC黏结强度的主要因素有保护层厚度、锚固长度和钢筋直径。Bae等[13]通过锚固试验研究发现:钢纤维体积分数由0增加到1%,钢筋与UHPC的黏结强度提高了1倍,由1%增加到2%,黏结强度提高幅度变小。Saleem等[14]研究了高强钢筋在UHPC中锚固长度,结果表明:直径9.5 mm和22.2 mm高强钢筋的锚固长度分别为12倍和18倍的钢筋直径。安明喆等[15]通过钢筋拔出试验,研究了变形钢筋直径和锚固长度对钢筋/活性粉末混凝土(RPC)黏结性能的影响,提出变形钢筋与RPC的极限黏结强度与锚固长度的计算公式。邓宗才等[16]通过54个中心拉拔、6个立方体偏心拉拔、6个棱柱体中心拉拔和6个板式中心拉拔锚固试件系统研究了钢筋埋长、保护层厚度、钢筋直径、RPC强度和钢纤维体积掺量等因素对钢筋/RPC黏结性能的影响规律。贾方方[17]通过5组直接拔出锚固试件研究了不同纤维体积掺量对钢筋/RPC黏结性能的影响,结果表明:纤维体积掺量从0增大到2%,黏结强度逐渐增大。

    采用直接拔出锚固试件对钢筋/UHPC黏结性能的研究较为充分,但加载时锚固试件钢筋受拉,周围UHPC受压,与实际结构构件受力不符,锚固试件加载端容易受到约束,限制UHPC的开裂,测得的黏结强度偏高,且目前尚未建立直接拔出锚固黏结与实际搭接黏结的关系,对实际应用指导有限。采用梁式搭接试件研究的钢筋/UHPC黏结性能与实际构件搭接受力最为相符。Dagenais等[6, 18]将UHPC应用于钢筋搭接长度不足的钢筋/混凝土受弯构件的加固中,分别进行了单调和滞回试验研究,研究结果表明钢筋/UHPC的搭接黏结强度约为普通混凝土的两倍,采用UHPC加固过的构件可以适用于地震区。Al-Quraishi等[19]试验了6根梁式钢筋搭接试件,研究了钢筋在UHPC中搭接性能,结果表明UHPC的劈裂是钢筋搭接失效的主要破坏模式。由于梁式搭接试件制作和加载过程较为复杂,研究数量有限。

    钢筋搭接对拉拔出试验能较好地反应实际构件的搭接受力,且能简化试验。徐有邻等[20]通过普通混凝土中钢筋搭接对拉拔出试验和梁中搭接钢筋传力对比试验,观察了搭接钢筋的传力机制、受力特征和破坏形态,发现对拉试验与梁中钢筋搭接试验结果基本相符。Graybeal[21]将强度为1 860 MPa的钢绞线在掺加不同纤维的UHPC中搭接,进行了对拉拔出试验,钢筋在掺加钢纤维的UHPC (抗压强度为162 MPa)中所需的搭接长度小于掺加PVA纤维的UHPC (抗压强度为134 MPa)。Lagier等[22]通过钢筋搭接对拉拔出试验研究了纤维体积掺量和搭接长度对搭接性能的影响,通过钢筋内部开槽粘贴应变片研究了钢筋沿搭接长度的应变分布。方志等[23]试验了39个钢筋/RPC搭接对拉拔出试件,发生破坏时,搭接区域的搭接黏结强度随搭接长度增大而略有减小,随RPC强度和配箍率的增大而增大,并研究了钢筋净距对搭接黏结强度的影响,在1倍钢筋直径时黏结强度达到最大。

    目前,针对钢筋/UHPC锚固试验的研究较充分,钢筋搭接试验的研究有限,且未建立钢筋/UHPC锚固和搭接之间的关系及指导实际设计的算法。本文进行了21组考虑搭接长度、纤维体积掺量和配箍率影响的钢筋/UHPC搭接对拉拔出试验,3组考虑锚固长度影响的钢筋/UHPC直接拔出锚固试验。研究钢筋锚固和搭接连接试件的破坏形态,分析钢筋搭接黏结强度的影响因素,参考相关文献,拟合得到钢筋/UHPC锚固和搭接试件的平均黏结强度计算公式及锚固和搭接长度计算公式,建立钢筋/UHPC锚固和搭接长度简化算法。

    设计了21组钢筋/UHPC搭接连接试件,每组3个试件完全相同,试件的主要变化参数有搭接长度、纤维体积掺量和配箍率。采用的钢筋直径为25 mm,搭接长度范围在3d~12d (d为钢筋直径)不等,以期发生多种破坏形态。纤维体积分数取值为2%、3%和4%。箍筋作为一种加强措施,其体积配箍率为0.67%、1.35%和2.25%。试件的截面尺寸为150 mm×150 mm,钢筋净距为10 mm;另外,设计了3组钢筋锚固试件作为对比试件,试件的截面尺寸为115 mm×115 mm,以保证与钢筋搭接连接试件的保护层厚度一致,均为45 mm;为了减轻试件端部对黏结段的影响,采用塑料套管将端部钢筋与UHPC隔离,长度为50 mm,因此,试件的长度为L+2×50 mm (L为搭接长度),试件尺寸如图1所示。试件参数及主要试验结果如表1所示。

    图  1  钢筋/超高性能混凝土(UHPC)搭接试件尺寸及制作(单位:mm)
    Figure  1.  Size and fabrication of steel bars/ultra high performance concrete (UHPC) lap-splice specimens (Unit: mm)

    试件编号中A和LS分别代表钢筋锚固试件和钢筋搭接连接试件,第2、3、4个符号的数字分别代表纤维体积分数(%)、配箍率(%)和搭接长度。例如:LS-2-0-3d表示钢筋搭接连接试件,纤维体积掺量为2%,配箍率为0,搭接长度为3倍的钢筋直径。

    表  1  钢筋锚固和搭接钢筋/UHPC试件参数及试验结果
    Table  1.  Parameters and test results of anchorage and lap-splice steel bars/UHPC specimens
    NumberNotationVf/%ρsv/%Lfcu/MPafc/MPaPy/kNPs/kNPu/kNτmt/MPaFailure mode
    1 A-2-0-3d 2 0 3d 117.1 103.6 190.4 197.6 33.6 SPF
    2 A-2-0-5d 5d 218.6 265.2 269.5 27.5 SPF
    3 A-2-0-7d 7d 220.4 284.6 298.1 21.7 SPF
    4 LS-2-0-3d 2 0 3d 117.1 103.6 111.9 130.2 22.1 SPF
    5 LS-2-0-5d 5d 143.4 171.8 17.5 SPF
    6 LS-2-0-7d 7d 173.3 208.3 15.1 SPF
    7 LS-2-0-8d 2 0 8d 110.1 100.9 219.1 223.4 234.2 14.9 SPF
    8 LS-2-0-10d 10d 215.6 246.9 266.0 13.6 SPF
    9 LS-2-0-12d 12d 217.6 272.8 293.7 12.5 SPF
    10 LS-3-0-8d 3 0 8d 116.6 105.5 217.2 245.8 253.2 16.1 SPF
    11 LS-3-0-10d 10d 219.1 265.7 284.8 14.5 SPF
    12 LS-3-0-12d 12d 216.3 285.9 298.8 12.7 RF
    13 LS-4-0-6d 4 0 6d 112 102 217.1 201.3 224.0 19.0 SPF
    14 LS-4-0-8d 8d 215.3 244.9 250.1 16.0 SPF
    15 LS-4-0-10d 10d 217.1 276.3 282.2 14.4 SPF
    16 LS-2-0.67-6d 2 0.67 6d 110.1 100.9 218.2 164.9 236.6 20.1 SPF
    17 LS-2-0.67-8d 8d 218.4 180.5 243.5 15.5 SPF
    18 LS-2-0.67-10d 10d 215.8 201.3 292.9 14.94 SPF
    19 LS-2-1.35-4d 2 1.35 4d 110.1 100.9 122.6 195.3 24.9 SPF
    20 LS-2-1.35-6d 6d 218.8 146.6 244.3 20.7 SPF
    21 LS-2-1.35-8d 8d 219.4 202.4 304.2 19.4 RF
    22 LS-2-2.25-4d 2 2.25 4d 110.1 100.9 128.1 206.0 26.2 SPF
    23 LS-2-2.25-6d 6d 219.4 167.7 257.9 21.9 SPF
    24 LS-2-2.25-8d 8d 214.5 216.0 302.8 19.3 RF
    Notes: d—Steel bar diameter; Vf—Fibre volume fraction; ρsv—Hoop ratio; L—Embedment length; fcu—Compressive strength of cube; fc—Compressive strength of prism; Py, Ps and Pu—Yield, slippage and peak loads in the test, respectively; τmt—Mean bond strength measured in the test; SPF and RF represent the splitting pull-out failure and steel bar rupture failure, respectively. The “A” and “LS” in notation system—Anchorage specimen and lap-splice specimen, respectively. The figures in the second, third and fourth symbol—Fibre volume fraction (%), stirrup ratio (%) and embedment length, respectively. For example, the notation of “LS-2-0-3d”—Splice specimen with 2% of fibre volume fraction, 0% of stirrup ratio and 3 bar diameters embedment.
    下载: 导出CSV 
    | 显示表格

    试验采用的UHPC配合比如表2所示,其中水泥选用P·O42.5级普通硅酸盐水泥;粉煤灰为Ⅰ级粉煤灰;细骨料采用石英砂,粒径范围为0.16~1.25 mm;硅灰选择无定型超细(非晶体)粉末,灰白色球状粉末,比表面积143 100 cm2/g;减水剂为聚羧酸系高效减水剂,减水率为30%,含固量32%;钢纤维选用上海某公司生产的带钩镀铜钢纤维,长度13 mm,直径0.22 mm,抗拉强度大于2 850 MPa。试件采用常温养护,试件成型后24 h拆模,浇水养护14天。

    表  2  UHPC配合比
    Table  2.  Mix proportions of UHPC
    NumberWater to
    binder ratio
    CementFly
    ash
    Silica
    fume
    Mineral
    powder
    Quartz
    sand
    SuperplasticizerVolume fraction of
    steel fiber Vf
    1 0.18 1.00 0.30 0.30 0.30 1.3 0.05 0.02
    2 0.18 1.00 0.30 0.30 0.30 1.3 0.05 0.03
    3 0.18 1.00 0.30 0.30 0.30 1.3 0.05 0.04
    下载: 导出CSV 
    | 显示表格

    每种UHPC配合比制作3个边长为100 mm的立方体试块和3个尺寸为100 mm×100 mm×300 mm的棱柱体试块分别测UHPC的立方体抗压强度(fcu)和棱柱体抗压强度(fc)。

    锚固和搭接钢筋的强度等级均为HRB400,直径为25 mm,箍筋和架立筋的强度等级为HPB300,直径为8 mm。钢筋力学性能如表3所示。

    表  3  钢筋力学性能
    Table  3.  Mechanical properties of steel bars
    Diameter/mmStrength gradeYield strength/MPaUltimate strength/MPa
    25 HRB400 447 611
    18 HRB400 436 608
    8 HPB300 364 540
    下载: 导出CSV 
    | 显示表格

    钢筋直接拔出锚固试验加载装置如图2(a)所示,钢筋锚固试验在100 t万能试验机上进行,采用位移控制加载,速率为0.5 mm/min。钢筋自由端安装位移计来测量自由端滑移量,通过TDS-530数据采集设备进行力和位移的采集。

    图  2  试验加载装置
    Figure  2.  Test loading devices

    钢筋搭接连接试验加载装置如2(b)所示,采用50 t锚杆拉拔仪通过手动加载对钢筋施加拉拔力,通过压力数显表人工读取拉力的大小;通过百分表来测量钢筋自由端与试块的相对滑移量;采用KD7016程控静态应变仪人工读取箍筋的应变。由于钢筋搭接连接试件两根钢筋不同轴,拉拔时会产生弯矩造成试件的转动,试块两侧放置限位钢垫块平衡弯矩。

    试件加载过程中的最大荷载称为极限荷载Pu,钢筋自由端出现滑移时的荷载称为滑移荷载Ps,屈服荷载Py实际是钢筋发生屈服时的荷载,各荷载值如表1所示。图3为各类型试件的极限荷载随锚固或搭接长度的变化关系,可以发现大部分试件的钢筋均发生屈服,一些试件的极限荷载接近甚至达到钢筋的极限受拉承载力。总体上,试件的极限荷载与钢筋锚固或搭接长度近似呈线性关系。

    图  3  钢筋/UHPC锚固或搭接试件极限荷载-埋长曲线
    Figure  3.  Ultimate load versus embedment length curves of anchorage and pull out lap-splice specimens of steel bars in UHPC

    图4为钢筋/UHPC 锚固或搭接试件破坏形态。如图所示,本次试验共出现2种破坏模式,分别是劈裂拔出破坏和钢筋拉断破坏,破坏模式主要受搭接长度的影响,搭接长度越大,试件提供的抗拉拔合力越大,越容易发生钢筋拉断破坏。此外,纤维体积掺量和配箍率也对破坏模式有一定的影响。

    图  4  钢筋/UHPC锚固或搭接试件破坏形态
    Figure  4.  Failure patterns of anchorage and lap-splice specimens of steel bars in UHPC

    所有的锚固试件和除LS-3-0-12d、LS-2-1.35-8d和LS-2-2.25-8d以外的搭接试件均发生劈裂拔出破坏。

    对于发生劈裂拔出破坏未配箍筋的试件,加载初期荷载较小,试件无明显现象;加载至约0.25Pu时试件出现端面放射状裂缝,荷载由钢筋加载端向自由端传递,钢筋与UHPC锚固试件加载端的界面已开始局部滑移,自由端附近界面处于黏结状态;约0.36Pu时,因斜向压肢的推力造成两筋间的分离趋势,引起环向应力,试件出现侧面纵向劈裂裂缝,此时裂缝长度和宽度均较小;随着荷载的增加,裂缝不断延伸且加宽,同时又有新的端面放射状裂缝和侧面纵向裂缝产生,当钢筋自由端出现微小滑移时,各试件滑移荷载在0.83Pu~0.98Pu范围内,此时,加载端到自由端的化学黏结力逐步被削弱、丧失,拉力主要依靠钢筋肋部的机械咬合力与钢筋表面的摩擦力传递,此后荷载增长缓慢,裂缝继续延伸和加宽,钢筋自由端滑移增大;当纵向裂缝即将贯通时,裂缝宽度急剧增大,试件达到极限荷载Pu,发生纵向劈裂拔出破坏。钢筋锚固试件破坏见图4(a),钢筋搭接连接试件破坏见图4(b)

    对于发生劈裂拔出破坏配有箍筋的搭接试件,与未配箍筋的试件相比,其侧面纵向开裂荷载有所提高,约为0.4Pu,滑移荷载在0.60Pu~0.74Pu范围内,钢筋出现滑移后,荷载仍然会有显著的提高;达到Pu时,侧面纵向裂缝宽度增大,但未完全贯通,钢筋自由端滑移加快,钢筋逐渐从UHPC中拔出,如图4(c)所示。箍筋对UHPC的约束作用延迟了纵向裂缝的产生,纵向裂缝出现后,箍筋应变快速增大,产生较大的约束力,限制侧面纵向裂缝的加宽和延伸,达到Pu时侧面纵向裂缝未贯通。

    试件LS-3-0-12d纤维体积分数为3%,试件LS-2-1.35-8d和LS-2-2.25-8d的体积配箍率分别为1.35%和2.25%,三组试件均发生钢筋拉断破坏。与劈裂拔出破坏相比,加载初期试件端部也出现放射状裂缝,继续加载侧面出现纵向裂缝,但之后试件裂缝发展缓慢甚至停止发展,随着荷载的不断增大,最终发生钢筋拉断破坏,见图4(d),钢筋自由端始终未出现滑移。3%的纤维体积分数、1.35%和2.25%的配箍率可以有效提供侧向约束,使试件只需较短的搭接长度(分别为12d、8d、8d)就发生了钢筋的拉断破坏。

    钢筋/UHPC黏结应力沿锚固或搭接长度分布不均匀,且长度越大黏结应力分布越不均匀。采用钢筋/UHPC平均黏结应力来评估其黏结性能,计算公式如下:

    τ=PπdL (1)

    式中:P为对拉荷载;d为钢筋直径;L为锚固或搭接长度。对应于发生黏结破坏的应力称为平均黏结强度。

    随着钢筋埋置长度的增大,钢筋拉拔应力由加载端向自由端传递的路径随之增大,可以延迟自由端的钢筋/UHPC黏结破坏,进而增大钢筋的极限荷载,如图3所示。但由于实际黏结应力分布不均匀,靠近加载端的黏结应力大,远离加载端的黏结应力小,增大埋置长度使远离加载端应力较小的部分变长了,因此,平均黏结应力随之减小,如图5所示。

    图  5  钢筋/UHPC平均黏结强度与埋置长度关系
    Figure  5.  Average bond strength versus embedded length of steel bars/UHPC

    图6展示了钢筋/UHPC 平均黏结强度与钢纤维体积分数关系。如图所示,钢纤维体积分数由2%提高到3%,在8d和10d的搭接长度时,平均黏结强度分别提高了8.0%和6.7%。钢纤维在基体中乱向分布,阻止了硬化过程中微裂纹的产生,在受力过程中,钢纤维会阻挠裂纹的扩展,迫使其改变方向,缓冲裂缝尖端处的应力集中,从而起到阻裂的作用[17]。有效地约束了UHPC,抑制了劈裂裂缝的发展,提高了钢筋与UHPC的黏结强度[24]。钢纤维体积分数由3%提高到4%,在8d和10d的搭接长度时,平均黏结强度出现了略微降低,分别降低了0.80%和0.83%,其原因可能是钢纤维掺量增大,影响了UHPC的和易性和钢纤维的分散性,导致UHPC的密实度降低,降低了钢筋/UHPC黏结性能。

    图  6  钢筋/UHPC平均黏结强度与钢纤维体积分数关系
    Figure  6.  Average bond strength versus fibers fraction of steel bars/UHPC

    试验过程中记录了每一级荷载作用下的箍筋应变,如图7所示,试件加载初期箍筋应变值较小,呈线性缓慢增长;随着荷载增加,试件内部出现裂缝,箍筋应变迅速增长,曲线斜率变大,达到极限荷载时,大部分箍筋达到屈服,强度得到充分发挥。

    图  7  钢筋/UHPC搭接试件箍筋应变-荷载曲线
    Figure  7.  Stirrup strains versus loads curves of steel bars lap-splice UHPC specimens

    配箍率对平均黏结强度的影响规律见图8,随着配箍率的增大平均黏结强度随之增大,箍筋可以对UHPC形成有效的约束,使钢筋周围UHPC处于多轴受压应力状态[25],钢筋之间斜向压肢的推力造成两筋间的分离趋势,会引起环向应力,箍筋可以抵消环向分力,有效抑制试件的纵向劈裂,进而提高黏结强度。

    图  8  钢筋/UHPC平均黏结强度与配箍率关系
    Figure  8.  Average bond strength versus stirrup ratio curves of steel bars/UHPC

    参考普通混凝土钢筋搭接强度拟合公式的形式[20],本文搜集了文献[15-17]中的钢筋/UHPC锚固试验数据,如表4所示,并根据本文的试验结果,拟合得到考虑钢筋直径、锚固长度、保护层厚度、纤维体积掺量和抗压强度影响的锚固黏结强度计算公式:

    表  4  钢筋/UHPC锚固和对拉拔出搭接试件试验数据
    Table  4.  Test data of anchorage specimens and pull out lap-splice specimens of steel bars in UHPC
    ReferenceNotationd/mmL/mmc/mmρsvfcu/MPaVfτut/MPa
    Anchorage specimen [15] φ14-50 14 50 68 0 147.78 0.023 37.07
    φ15-50 16 50 67 0 147.78 0.023 33.28
    φ16-50 18 50 66 0 147.78 0.023 29.87
    φ17-50 18 75 66 0 147.78 0.023 28.94
    [16] H1-LZ-8-24 8 24 71 0 121.77 0.02 55.3
    H1-LZ-8-32 8 32 71 0 121.77 0.02 45.7
    H1-LZ-10-30 10 30 70 0 121.77 0.02 46.1
    H1-LZ-10-40 10 40 70 0 121.77 0.02 42.9
    H2-LZ-16-48 16 48 67 0 132.39 0.02 52.7
    H2-LZ-16-64 16 64 67 0 132.39 0.02 42.9
    H2-LZ-16-80 16 80 67 0 132.39 0.02 34.1
    H2-LZ-18-54 18 54 66 0 132.39 0.02 55
    H2-LZ-18-72 18 72 66 0 132.39 0.02 42.3
    H3-LZ-6-18 6 18 72 0 153.09 0.03 51.1
    H3-LZ-8-24 8 24 71 0 153.09 0.03 70.5
    H3-LZ-8-32 8 32 71 0 153.09 0.03 52.8
    H3-LZ-10-30 10 30 70 0 153.09 0.03 62.2
    H2-NZ-16-12 16 48 12 0 132.39 0.02 31.1
    H2-NZ-16-22 16 48 22 0 132.39 0.02 36
    H2-NZ-16-32 16 48 32 0 132.39 0.02 41.9
    H2-NZ-16-42 16 48 42 0 132.39 0.02 47.7
    H2-NZ-16-52 16 48 52 0 132.39 0.02 48.8
    H2-NZ-16-62 16 48 62 0 132.39 0.02 52.8
    H3-LP-8-10 8 40 10 0 153.09 0.03 29.9
    H3-LP-8-15 8 40 15 0 153.09 0.03 29.1
    [17] P0.0 16 50 67 0 79.81 0 29.7
    P0.5 16 50 67 0 92.27 0.005 31.18
    P1.0 16 50 67 0 114.30 0.01 32.05
    P1.5 16 50 67 0 117.02 0.015 36.72
    P2.0 16 50 67 0 128.58 0.02 38.12
    Lap-splice specimen [23] L100-R100-D1-S0 20 100 45 0 96.03 0.02 17.14
    L100-R100-D1-S34 20 100 45 0.0034 96.03 0.02 18
    L100-R100-D1-S75 20 100 45 0.0075 96.03 0.02 19.03
    L100-R120-D1-S0 20 100 45 0 117.36 0.02 18.95
    L100-R120-D1-S34 20 100 45 0.0034 117.36 0.02 19.9
    L100-R120-D1-S75 20 100 45 0.0075 117.36 0.02 21.04
    L100-R150-D1-S0 20 100 45 0 141.39 0.02 20.36
    L100-R150-D1-S34 20 100 45 0.0034 141.39 0.02 22.12
    L100-R150-D1-S75 20 100 45 0.0075 141.39 0.02 23.35
    L150-R100-D1-S34 20 150 45 0.0034 96.03 0.02 17.52
    L150-R120-D1-S34 20 150 45 0.0034 96.03 0.02 19.18
    L200-R100-D1-S34 20 200 45 0.0034 96.03 0.02 14.75
    L200-R100-D1-S34 20 200 45 0.0034 96.03 0.02 13.74
    Notes: d—Steel bar diameter; L—Embedment length; c—Thickness of UHPC cover; ρsv—Hoop ratio; fcu—Compressive strength of cube; Vf—Fibre volume fraction; τut—Test value of ultimate average bond strength.
    下载: 导出CSV 
    | 显示表格
    τua=(0.53+2.31dlsa)(3.633+0.217cd)(0.604+1.839Vf)fc (2)

    回归公式的相关系数为0.97;适用范围:相对保护层厚度c/d在[1,5],纤维体积掺量Vf在[0,0.03],抗压强度fc在[80,150]。式中:τua为钢筋/UHPC极限锚固黏结强度;d为钢筋直径;lsa为锚固长度;c为保护层厚度,当相对保护层厚度c/d大于5时,取为5;fc为UHPC单轴抗压强度。

    文献[23]通过试验数据拟合回归了钢筋搭接黏结强度公式,但没有考虑UHPC中纤维掺量因素的影响,本试验进一步丰富了搭接试验的数据,对文献[23]的公式进行验证,发现与试验值具有较大误差,如图9所示。因此,结合本文试验结果并参考文献[23]的试验数据(表4),拟合得到考虑钢筋直径、搭接长度、保护层厚度、配箍率、纤维体积掺量和抗压强度影响的钢筋/UHPC搭接黏结强度计算公式:

    图  9  钢筋搭接强度拟合公式计算值与试验值对比
    Figure  9.  Comparison between the calculated value and the test value of the fitting formula of the steel lap-splice strength
    τul=(0.36+2.02dlsl)(0.86+0.57cd)(0.83+2ρsv+11.65Vf)fc (3)

    回归公式的相关系数为0.99,适用范围:相对保护层厚度c/d在[1.8,2.8],配箍率ρsv在[0,0.0225],纤维体积掺量Vf在[0.02,0.04],抗压强度fc在[90,150]。式中:τul为钢筋/UHPC极限搭接黏结强度;lsl为搭接长度;ρsv为试件配箍率。拟合公式计算值与试验值吻合良好,如图9所示。

    为了验证拟合公式的有效性,对文献[6]和[18]的梁式搭接试件的黏结强度进行计算并与试验结果进行对比,如表5所示,计算值与试验值比值的平均值为1.15,变异系数为0.29,与梁式试件试验结果吻合较好。

    表  5  钢筋/UHPC搭接梁式试件黏结强度拟合公式验证
    Table  5.  Verification of the fitting formula for lap-splice bond strength of beam lap-splice steel bars/UHPC specimens
    ReferenceNotationd/mmL/mmc/mmfc/MPaVfτut/MPaτuf/MPaτuf/τut
    Beam lap-splice specimen [6] 1-12-25-L 25 300 45 130 0.03 10.8 13.40 1.26
    2-12-25-L 25 300 45 130 0.03 9.8 13.40 1.39
    1-18-25-L 25 450 45 130 0.03 6.8 11.98 1.96
    1-12-35-L 35 420 45 130 0.03 9.8 11.32 1.15
    1-18-35-L 35 630 45 130 0.03 6.11 10.12 1.81
    1-6-25-L 25 150 45 130 0.03 19.6 17.67 0.74
    1-6-25-L1 25 150 45 130 0.03 19.6 17.67 0.74
    1-12-25-L1 25 300 45 130 0.03 9.8 13.40 1.39
    1-6-35-L 35 210 45 130 0.03 16.23 14.92 0.74
    1-6-35-L½ 35 210 45 130 0.03 12.32 14.92 0.97
    1-12-35-L½ 35 420 45 130 0.03 9.16 11.32 1.24
    [18] 25-12-L-1% 25 300 25 125 0.01 9.5 8.00 1.04
    25-12-L-2% 25 300 25 124 0.02 10.4 8.94 0.94
    25-12-L-3% 25 300 25 114 0.03 10.5 9.51 0.90
    25-12-R-3% 25 300 25 114 0.03 10 9.51 0.94
    35-18-L-3% 35 630 35 114 0.03 8.2 8.50 1.13
    35-18-R-3% 35 630 35 114 0.03 7.2 8.50 1.28
    Average value 1.15
    Variation coefficient 0.29
    Notes: fc—Uniaxial compressive strength; τut—Test value of ultimate average bond strength; τuf—Value of ultimate average bond strength calculated by the Eq. (3).
    下载: 导出CSV 
    | 显示表格

    定义钢筋达到屈服强度fy时,钢筋从UHPC中不被拨出所需的最小锚固和搭接长度分别为临界屈服锚固长度lsay和临界屈服搭接长度lsly;钢筋达到极限强度fu时,钢筋从UHPC中不被拨出所需的最小锚固和搭接长度分别为临界极限锚固长度lsau和临界极限搭接长度lslu。由图3可知,各类型试件的极限荷载随锚固或搭接长度的变化趋势近似为线性,因此,各类试件的临界屈服锚固长度lsayt或搭接长度lslyt (合称为临界屈服长度lsyt)以及临界极限锚固长度lsaut或搭接长度lslut (合称为临界极限长度lsut)可按线性规律近似确定,如表6图10所示。随着纤维体积掺量和配箍率的增大,临界屈服和极限长度逐渐减小。

    表  6  钢筋/UHPC锚固和搭接长度试验值与计算值
    Table  6.  Test values and calculated values of development length and splice length of steel bars/UHPC
    TypeMinimum anchorage or lap length of steel bar yieldMinimum anchorage or lap length of steel bar rupture
    lsyACIlsyGBlsyslsyflsytlsuACIlsuGBlsuslsuflsut
    Anchorage specimen 28.6d 11.2d 5.3d 3.7d 3.6d 39.1d 15.3d 7.2d 6.6d 7.1d
    2.25vol% hoops 20.9d 17.9d 10.5d 5.8d 4.5d 28.6d 24.4d 14.4d 10.1d 7.6d
    1.35vol% hoops 20.9d 17.9d 10.5d 6.4d 4.9d 28.6d 24.4d 14.4d 11.0d 8.1d
    0.67vol% hoops 20.9d 17.9d 10.5d 7.1d 4.8d 28.6d 24.4d 14.4d 11.9d 10.6d
    4vol% fibers 28.9d 17.6d 10.6d 6.5d 5.8d 39.4d 24.0d 14.5d 11.1d 13.2d
    3vol% fibers 28.3d 16.4d 10.4d 7.5d 38.7d 22.4d 14.3d 12.5d 12.1d
    2vol% fibers 29.0d 17.9d 10.5d 9.3d 7.3d 39.7d 24.4d 14.4d 15.0d 12.6d
    Notes: lsyACI, lsyGB, lsys and lsyf—Minimum anchorage or lap length of steel bar yield calculated by the ACI 318—19[27], GB 50010—2010[26], simplified algorithm and fitting formula, respectively; lsuACI, lsuGB, lsus, and lsuf—Minimum anchorage or lap length of steel bar rupture calculated by the ACI 318—19[27], GB 50010—2010[26], simplified algorithm and fitting formula, respectively; lsyt—Test value of minimum anchorage or lap length of steel bar yield; lsut—Test value of minimum anchorage or lap length of steel bar rupture.
    下载: 导出CSV 
    | 显示表格
    图  10  不同类型钢筋/UHPC锚固或搭接试件的临界长度计算值与试验值
    Figure  10.  Test and calculation values of critical length for different types of anchorage and pull out lap splice steel bars/UHPC specimens

    《混凝土结构设计规范》GB 50010—2010[26]中规定受拉钢筋的锚固和搭接长度按下式进行计算:

    ls=αξaξlfyftd (4)

    式中:α为钢筋的外形系数,考虑钢筋的表面类型对黏结强度的影响,对本文钢筋取0.14;ξa为锚固或搭接长度修正系数,主要考虑了钢筋直径大于25 mm,表面涂有环氧树脂,有施工扰动,实配钢筋面积大于计算钢筋面积以及保护层厚度大于3d或5d等情况的影响;ξ1为纵向受拉钢筋搭接长度修正系数,主要考虑了纵向搭接钢筋接头面积百分率,对本文试件取1.6,对于锚固试件取1.0。

    美国规范ACI 318—19[27]根据表7将搭接接头分为A、B两类,其中基本的锚固或搭接长度按下式计算:

    表  7  受拉钢筋/UHPC搭接长度[27]
    Table  7.  Lap splice lengths of deformed steel bars/UHPC in tension[27]
    As,p/As,rMaximum percent of As spliced
    within required lap length/%
    Splice typeLap splice lengths ls
    ≥2 50 A Greater of: 1.0ld and 304.8 mm
    100 B Greater of: 1.3ld and 304.8 mm
    <2 All cases B
    Note: As,p/As,r—Ratio of area of reinforcement provided to area of reinforcement required by analysis at splice location.
    下载: 导出CSV 
    | 显示表格
    ldd=3fy40fc(c+Ktrd) (5)
    Ktr=40Atrsn (6)

    式中:为避免发生钢筋拔出破坏:规定(c+Ktr)/d 2.5f为钢筋应力;fc混凝土圆柱体抗压强度,由于缺少抗压强度69 MPa以上的试验数据,限定\sqrt {{f_{\rm{c}}}} \leqslant 8.3,但Azizinamini等[28]和Hamad等[29]均认为这条限定并不合理;c为保护层厚度;d为钢筋直径;Atr为垂直于劈裂面的横向钢筋面积;s为横向钢筋间距;n为搭接钢筋数量。由公式可以看出美国规范考虑了混凝土抗压强度、保护层厚度、钢筋直径和箍筋对搭接长度的影响。本文搭接接头按B类接头进行计算。

    分别采用GB 50010—2010规范[26]及ACI 318—19规范[27]对钢筋/UHPC锚固和搭接长度进行计算,如表6图10所示,对比试验结果可知:两规范计算的临界锚固和搭接长度偏于保守,尤其对于无箍筋的试件,美国ACI 318—19规范[27]的计算结果过于保守。

    结合式(1)和式(2),可以推出钢筋/UHPC的锚固长度计算公式:

    \frac{{{l_{{\rm{sa}}}}}}{d} = \frac{f}{{2.22\left(0.86 + 0.57\dfrac{c}{d}\right)(0.83 + 11.56{V_{\rm{f}}})\sqrt {{f_{\rm{c}}}} }} - 5.61 (7)

    式中:{l_{{\rm{sa}}}}/d称为相对锚固长度。f取钢筋屈服强度fy时,得临界屈服锚固长度lsayf;当f取钢筋极限强度fu时,得到临界极限锚固长度lsauf

    同样结合式(1)和式(3),可以推出钢筋/UHPC搭接长度计算公式:

    \begin{split} &\frac{{{l_{{\rm{sl}}}}}}{d} =\\ &\dfrac{f}{{1.44\left(0.86 + 0.57\dfrac{c}{d}\right)(0.83 + 2\sqrt {{\rho _{{\rm{sv}}}}} + 11.65{V_{\rm{f}}})\sqrt {{f_{\rm{c}}}} }} - 5.61 \end{split} (8)

    式中:f取钢筋屈服强度fy时,得临界屈服搭接长度lslyff取钢筋极限强度fu时,得到临界极限搭接长度lsauf

    临界锚固和搭接长度拟合公式计算值如表6图10所示,可知拟合公式计算值与试验值吻合良好。

    为便于工程实际应用,参考GB 50010—2010规范[26]的算法,提出钢筋/UHPC临界锚固和搭接长度简化计算方法。钢筋搭接因仅有部分周径参与力的传递,因此,钢筋的搭接长度较锚固长度长[30]。GB 50010—2010规范[26]以锚固长度为基准,对于纵向搭接钢筋接头面积百分率为25%、50%和100%的情况,搭接长度分别取1.2、1.4和1.6倍的锚固长度。

    式(4)实际上是根据受力平衡条件建立的锚固长度计算公式{l_{\rm{s}}} = \dfrac{{{f_{\rm{y}}}d}}{{4{\tau _{\rm{u}}}}}的变形,采用混凝土的单轴抗拉强度ft替代τu来表征混凝土强度对锚固长度的影响,式(4)中的外形系数\alpha = \dfrac{{{f_{\rm{t}}}}}{{4{\tau _{\rm{u}}}}}。原海燕[31]对比了UHPC与普通C40混凝土的各项力学性能,UHPC单轴抗拉强度为普通C40混凝土的1.5倍,抗压强度和极限黏结强度均约为普通混凝土的3倍。因此,对于UHPC采用其抗压强度替代τu来表征UHPC强度对锚固长度的影响较为合理。此时,定义外形系数{\alpha _{\rm{u}}} = \dfrac{{\sqrt {{f_{\rm{c}}}} }}{{4{\tau _{\rm{u}}}}},通过对本文试验及参考文献[15-17]的数据进行分析计算得αu的取值范围在0.04~0.12之间,因此偏安全的取为0.12。得到钢筋/UHPC锚固长度计算公式:

    {l_{\rm{s}}} = {\alpha _{\rm{u}}}\frac{f}{{\sqrt {{f_{\rm{c}}}} }}d (9)

    式中:f取钢筋屈服强度fy时得临界屈服锚固长度lsayf取钢筋极限强度fu时得临界极限锚固长度lsaufc为UHPC单轴抗压强度。

    钢筋搭接因仅有部分周径参与力的传递,因此,钢筋的搭接长度较锚固长度长。本文采用直径25 mm的钢筋,相同纤维体积分数(2%)、保护层厚度(45 mm)和UHPC抗压强度(103.6 MPa)且未配箍筋的情况下,分别进行了3d、5d和7d埋置长度的锚固和搭接试验,由表6图10可知钢筋/UHPC临界屈服锚固和搭接长度分别为3.6d和7.3d,临界极限锚固和搭接长度分别为7.1d和12.6d,可得UHPC中变形钢筋的临界搭接长度约为其临界锚固长度的2倍,验证了文献[23]所推得的结论。因此,钢筋/UHPC搭接长度可由式(9)计算出的锚固长度乘以2得到。

    简化算法计算结果如表6图10所示,式(9)未考虑纤维体积掺量和配箍率的影响,计算结果较为保守,但相比于GB 50010—2010规范[26]及ACI 318—19规范[27]的计算值较为准确。

    文献[6]中直径25 mm的钢筋在梁跨中搭接于抗压强度130 MPa、纤维体积分数为3%的UHPC中,保护层厚度为30 mm且未配箍筋,在搭接长度为12d时,单调荷载作用下未发生搭接破坏,分别采用拟合公式和简化算法计算的临界极限搭接长度为12.7d和13.6d,与试验结果相比较为吻合且偏于安全。

    通过21组钢筋搭接对拉拔出试验和3组钢筋直接拔出锚固试验,并参考相关文献数据,得出以下结论:

    (1)钢筋搭接试验主要出现劈裂拔出破坏和钢筋拉断破坏2种破坏模式,增大搭接长度和配箍率以及适当增大纤维掺量均有利于试件由劈裂拔出破坏变为钢筋拉断破坏;

    (2)试验得出各类型试件的临界屈服和极限搭接长度,对直径为25 mm的HRB400带肋钢筋,在抗压强度为110.1 MPa、纤维体积分数为2%的超高性能混凝土(UHPC)中,保护层厚度为45 mm且未配箍筋时,其临界屈服和极限搭接长度分别为7.3d和12.6d (d为钢筋直径),增加配箍率和适当增大纤维掺量均能减小钢筋/UHPC临界搭接长度;

    (3)随搭接长度的增大,钢筋/UHPC平均黏结强度减小;钢纤维掺量的增大及配箍率的增大,提高了箍筋对UHPC的约束作用,有效限制了试件的纵向劈裂,黏结强度随之增大;

    (4)采用中国GB 50010—2010规范[26]和ACI 318—19规范[27]计算的钢筋/UHPC锚固和搭接长度与试验结果相比均过于保守。参考相关文献的试验数据,并结合本文的试验结果,拟合得到钢筋锚固试件、钢筋搭接试件的平均黏结强度计算公式及临界锚固和搭接长度计算公式,且采用梁式搭接试验的结果对钢筋/UHPC黏结强度拟合公式进行验证,结果较为吻合。参考中国规范的算法建立了钢筋/UHPC临界锚固和搭接长度简化算法,未考虑纤维掺量和配箍率的影响,计算结果较为保守,相比于GB 50010—2010规范[26]及ACI 318—19规范[27]的计算值较为准确。

  • 图  1   环氧树脂E-51@海藻酸钙微胶囊(SA)制备示意图

    Figure  1.   Preparation diagram of epoxy resin E-51@calcium alginate absorbent microcapsule (SA)

    图  2   “三明治”夹心结构试件示意图

    Figure  2.   "Sandwich" structure specimen diagram

    图  3   (a)环氧树脂@海藻酸钙微胶囊(SA)的SEM图像;(b)去除核环氧树脂E-51的SA内部SEM图像

    Figure  3.   (a) SEM image of calcium alginate@epoxy resin (SA) morphology; (b) SEM image of the internal SA of nuclear epoxy resin E-51

    图  4   硅烷偶联剂修饰后微胶囊表面EDS面扫:(a) KH-1扫描位置;(b) KH-1表面N元素;(c) KH-1表面Si元素;(d) KH-2扫描位置;(e) KH-2表面N元素;(f) KH-2表面Si元素;(g) KH-3扫描位置;(h) KH-3表面N元素;(i) KH-3表面Si元素

    Figure  4.   EDS surface scan images of microcapsules modified with silane coupling agent: (a) KH-1 scanning position; (b) KH-1 surface N elements; (c) KH-1 surface Si elements; (d) KH-2 scanning position; (e) KH-2 surface N elements; (f) KH-2 surface Si elements; (g) KH-3 scanning position; (h) KH-3 surface N elements; (i) KH-3 surface Si elements

    图  5   微胶囊与水泥基体界面结合处形貌SEM图:(a) SA;(b) KH-1;(c) KH-2;(d) KH-3

    Figure  5.   SEM images of the interface between microcapsule and cement matrix: (a) SA; (b) KH-1; (c) KH-2; (d) KH-3

    图  6   SA和KH-3组样品不同位置处的维氏硬度:(a)测试位置示意图;(b)维氏硬度

    Figure  6.   Vickers hardness of SA and KH-3 samples at different locations: (a) Schematic diagram of test locations; (b) Vickers hardness

    图  7   掺SA、KH-1、KH-2和KH-3样品的界面粘结强度

    Figure  7.   Interfacial bonding strength of samples doped with SA, KH-1, KH-2 and KH-3

    图  8   硅烷偶联剂KH792结构式

    Figure  8.   Silane coupling agent KH792 structural formula

    图  9   水解处理法修饰微胶囊反应示意图

    Figure  9.   Schematic diagram of the hydrolysis treatment method for modifying microcapsules

    图  10   直接处理法修饰微胶囊反应示意图

    Figure  10.   Schematic diagram of the direct treatment method for modifying microcapsules

    图  11   对照组砂浆、掺SA砂浆和掺KH-3砂浆自修复前后的抗压强度

    Figure  11.   Compressive strength of control group mortar, SA mortar and KH-3 mortar before and after self-repair

    图  12   对照组砂浆、掺SA砂浆和掺KH-3砂浆试样自修复前后的抗水渗透性

    Figure  12.   Water permeability resistance of mortar, SA mortar and KH-3 mortar samples in control group before and after self-repair

    表  1   实验所用P·I 42.5硅酸盐水泥的化学成分及熟料矿物组成

    Table  1   Chemical composition and clinker mineral composition of P·I 42.5 Portland cement used in the experiment

    Constitute SiO2 Fe2O3 CaO MgO SO3 Na2O eq f-CaO 2CaO·SiO2 3CaO·SiO2 3CaO·Al2O3 4CaO·Al2O3·Fe2O3
    Content/wt% 22.15 3.12 64.76 2.98 0.65 0.57 0.90 19.01 59.42 6.36 9.48
    Notes: Sodium oxide equivalent (Na2O eq) is the total alkali content in Portland cement, expressed as Na2O; Free calcium oxide (f-CaO) refers to the unreacted calcium oxide present in Portland cement clinker.
    下载: 导出CSV

    表  2   实验所用 ISO 标准砂粒径分布

    Table  2   ISO standard sand particle diameter distribution used in the experiment

    Square hole side length/mm Cumulative screening margin/% Square hole side length/mm Cumulative screening margin/%
    2.0 0 0.5 67±5
    1.6 7±5 0.16 87±5
    1.0 33±5 0.08 99±1
    下载: 导出CSV

    表  3   偶联剂处理微胶囊的工艺编号

    Table  3   Processing code for coupling agent-treated microcapsules

    Serial number Process mode mKH792mSA
    KH-1 Hydrolysis method 1∶10
    KH-2 Direct method 1∶1
    KH-3 Direct method 2∶1
    Note: mKH792mSA—Mass ratio of silane coupling agent KH792 to epoxy resin E-51@calcium alginate microcapsules.
    下载: 导出CSV
  • [1] 房国豪, 陈锦妹, 王琰帅, 等. 微胶囊自修复混凝土研究进展[J]. 硅酸盐学报, 2023, 51(9): 2423-2432.

    FANG Guohao, CHEN Jinmei, WANG Yanshuai, et al. Research development on microencapsulated self-healing concrete[J]. Journal of the Chinese Ceramic Society, 2023, 51(9): 2423-2432(in Chinese).

    [2]

    YANG Z, HOLLAR J, HE X, et al. A self-healing cementitious composite using oil core/silica gel shell microcapsules[J]. Cement & Concrete Composites, 2011, 33(4): 506-512.

    [3]

    WHITE S R, SOTTOS N R, GEUBELLE P H, et al. Correction: Autonomic healing of polymer composites[J]. Nature, 2002, 415: 817. DOI: 10.1038/415817a

    [4]

    XUE C, LI W, LI J, et al. A review study on encapsulation-based self-healing for cementitious materials[J]. Structural Concrete, 2019, 20(1): 198-212. DOI: 10.1002/suco.201800177

    [5]

    MA Y, LIU J, ZHANG Y, et al. Mechanical behavior and self-healing mechanism of polyurea-based double-walled microcapsule/epoxy composite films[J]. Progress in Organic Coatings, 2021, 157: 106283. DOI: 10.1016/j.porgcoat.2021.106283

    [6]

    WANG X F, HAN R, HAN T L, et al. Determination of elastic properties of urea-formaldehyde microcapsules through nanoindentation based on the contact model and the shell deformation theory[J]. Materials Chemistry and Physics, 2018, 215: 346-354. DOI: 10.1016/j.matchemphys.2018.05.041

    [7]

    LYU L, ZHANG H, SCHLANGEN E, et al. Experimental and numerical study of crack behaviour for capsule-based self-healing cementitious materials[J]. Construction and Building Materials, 2017, 156: 219-229. DOI: 10.1016/j.conbuildmat.2017.08.157

    [8]

    MA X, YUAN Q, LIU J, et al. Effect of water absorption of SAP on the rheological properties of cement-based materials with ultra-low w/b ratio[J]. Construction and Building Materials, 2019, 195: 66-74. DOI: 10.1016/j.conbuildmat.2018.11.050

    [9]

    MAULUDIN L M, ZHANG X, RABCZUK T. Computational modeling of fracture in encapsulation-based self-healing concrete using cohesive elements[J]. Composite Structures, 2018, 196: 63-75.

    [10]

    LYU L, GUO P, XING F, et al. Trigger efficiency enhancement of polymeric microcapsules for self-healing cementitious materials[J]. Construction and Building Materials, 2020, 235: 117443. DOI: 10.1016/j.conbuildmat.2019.117443

    [11] 张璐, 毛倩瑾, 伍文文, 等. 吸水性微胶囊界面修饰提高水泥基材料抗渗性研究[J]. 硅酸盐通报, 2022, 41(8): 2663-2671. DOI: 10.3969/j.issn.1001-1625.2022.8.gsytb202208008

    ZHANG Lu, MAO Qianjin, WU Wenwen, et al. Interface modification of water absorbent microcapsules to improve impermeability of cement-based materials[J]. Journal of the Chinese Ceramic Society, 2022, 41(8): 2663-2671(in Chinese). DOI: 10.3969/j.issn.1001-1625.2022.8.gsytb202208008

    [12]

    SOUZA L, AI-TABBAA A. Microfluidic fabrication of microcapsules tailored for self-healing in cementitious materials[J]. Construction and Building Materials, 2018, 184: 713-722. DOI: 10.1016/j.conbuildmat.2018.07.005

    [13]

    MAO Q J, CHEN J Y, QI W J, et al. Improving self-healing and shrinkage reduction of cementitious materials using water absorbing polymer microcapsules[J]. Materials, 2022, 15(3): 847.

    [14]

    MAO Q J, CHEN J Y, WU W W, et al. Multiple self-healing effects of water-absorbing microcapsules in cementitious materials[J]. Polymers, 2023, 15(2): 428.

    [15] 郎风超, 朱静, 李云芳, 等. SEM环境下纤维推出技术结合电子束云纹技术表征复合材料界面细观力学性能[J]. 复合材料学报, 2020, 37(6): 1383-1389.

    LANG Fengchao, ZHU Jing, LI Yunfang, et al. Characterization of interfacial meso-mechanical properties of composites using fiber push-out under SEM combing with electron beam moiré method[J]. Acta Materiae Compositae Sinica, 2020, 37(6): 1383-1389(in Chinese).

    [16] 戚亮亮, 程乐乐, 余木火, 等. Ⅳ型高压储氢气瓶用碳纤维复合材料界面表征与分析[J]. 合成纤维, 2023, 52(4): 28-32.

    QI Liangliang, CHENG Lele, YU Muhuo, et al. Interface characterization and analysis of carbon fiber composites for type IV high-pressure hydrogen storage cylinder[J]. Synthetic Fiber in China, 2023, 52(4): 28-32(in Chinese).

    [17]

    JIN X, WU G. Quasi-in-situ analysis of adhesion failure at reduced iron/substrate interface of advanced high strength steel[J]. Materials Characterization, 2023, 197: 112712. DOI: 10.1016/j.matchar.2023.112712

    [18] 徐晶, 王彬彬. 浆/集界面纳米改性的多尺度力学表征[J]. 电子显微学报, 2015, 34(6): 492-497. DOI: 10.3969/j.issn.1000-6281.2015.06.008

    XU Jing, WANG Binbin. Multi-scale mechanical characterization of nanoscale modification of slurry/collector interface[J]. Journal of Chinese Electron Microscopy Society, 2015, 34(6): 492-497(in Chinese). DOI: 10.3969/j.issn.1000-6281.2015.06.008

    [19] 邱博, 邢书明, 董琦. 颗粒增强金属基复合材料界面结合强度的表征: 理论模型、有限元模拟和实验测试[J]. 材料导报, 2019, 33(5): 862-870. DOI: 10.11896/cldb.201905019

    QIU Bo, XING Shuming, DONG Qi. Characterization of interfacial bonding strength of particles reinforced metal matrix composites: Theory model, finite element simulation and experimental test[J]. Materials Reports, 2019, 33(5): 862-870(in Chinese). DOI: 10.11896/cldb.201905019

    [20]

    SHI C, WANG X, ZHAO Y, et al. Bond strength and interface characteristics between magnesium phosphate cement mortar and ordinary Portland cement concrete in a frigid environment[J]. International Journal of Pavement Engineering, 2024, 25(1): 2318610. DOI: 10.1080/10298436.2024.2318610

    [21] 中华人民共和国住房和城乡建设部. 挤塑聚苯板(XPS)薄抹灰外墙外保温系统材料: GB/T 30595—2014[S]. 北京: 中国标准出版社, 2014.

    Ministry of Housing and Urban-Rural Development of the People's Republic of China. Extruded polystyrene board (XPS) thin plaster external insulation system material: GB/T 30595—2014[S]. Beijing: Standards Press of China, 2014(in Chinese).

    [22] 中华人民共和国国家质量监督检验检疫总局, 中国国家标准化管理委员会. 干混砂浆物理性能试验方法: GB/T 29756—2013[S]. 北京: 中国标准出版社, 2013.

    General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China. Test method for physical properties of dry mixed mortar: GB/T 29756—2013[S]. Beijing: Standards Press of China, 2013(in Chinese).

    [23] 中华人民共和国住房和城乡建设部. 建筑砂浆基本性能试验方法标准: JGJ/T 70—2009[S]. 北京: 中国建筑工业出版社, 2009.

    Ministry of Housing and Urban-Rural Development of the People's Republic of China. Standard of test method for basic properties of building mortar: JGJ/T 70—2009[S]. Beijing: China Architecture & Building Press, 2009(in Chinese).

    [24]

    LLOYD D J, GALLERNEAULT M, WAGSTAFF R B. The deformation of clad aluminum sheet produced by direct chill casting[J]. Metallurgical and Materials Transactions A, 2010, 41: 2093-2103.

    [25]

    ZHANG Q, GAO F, ZHANG C, et al. Enhanced dielectric tunability of Ba0.6Sr0.4TiO3/poly(vinylidene fluoride) composites via interface modification by silane coupling agent[J]. Composites Science and Technology, 2016, 129: 93-100. DOI: 10.1016/j.compscitech.2016.04.016

    [26]

    LI H, WANG R, HU H, et al. Surface modification of self-healing poly(urea-formaldehyde) microcapsules using silane-coupling agent[J]. Applied Surface Science, 2008, 255(5): 1894-1900. DOI: 10.1016/j.apsusc.2008.06.170

  • 期刊类型引用(4)

    1. 曹邵文,周国庆,蔡琦琳,叶庆,庞昊强,吴玺. 太阳能电池综述:材料、政策驱动机制及应用前景. 复合材料学报. 2022(05): 1847-1858 . 本站查看
    2. 刘玉梅,温馨,孟翔飞. 基于技术轨道跃迁的突破性技术预测方法及应用研究. 情报杂志. 2021(11): 39-45+15 . 百度学术
    3. 王明序,许子傲,葛明桥,高强. 浅色导电纤维的发展及其最新应用. 丝绸. 2020(01): 37-42 . 百度学术
    4. 刘璇,李必奎,李明,王鹏波. 铜基碳纳米管复合薄膜载流性能分析. 化工进展. 2018(12): 4782-4790 . 百度学术

    其他类型引用(2)

  • 环氧树脂E-51@海藻酸钙微胶囊作为一种吸水性微胶囊,具有吸-释水性能,因而兼具自修复与内养护功能,能够长期稳定、多次发挥自修复作用,对混凝土/砂浆有良好的减缩作用。但由于吸水性微胶囊在水泥硬化过程中会随着基体湿度降低释放出水分、体积收缩,导致微胶囊与水泥基体界面结合力较弱,降低了微胶囊的裂缝触发破裂几率,自修复作用无法充分发挥。

    本文利用硅烷偶联剂KH792对环氧树脂E-51@海藻酸钙微胶囊进行表面修饰,以改善微胶囊与水泥基体的界面结合,提升自修复效果。采用扫描电镜、显微硬度测试和拉拔试验等分析测试手段从微观、介观到宏观多尺度表征微胶囊-水泥基体的界面结合情况,并通过砂浆试件损伤修复后的抗压强度和抗水渗透性的恢复率来评价自修复效果。研究表明,海藻酸钙@环氧树脂E-51微胶囊经硅烷偶联剂修饰后,界面结合更为紧密,界面处显微硬度提高了159%,界面粘结强度提高了67%;掺加4wt%(水泥质量)微胶囊的砂浆,荷载损伤修复后的抗压强度恢复率103%,水压力损伤修复后抗渗性恢复率达到118%。硅烷偶联剂表面修饰显著提升了吸水性微胶囊与水泥基体的界面结合情况,水泥基材料自修复效果增强。

    含不同微胶囊砂浆的界面粘结强度

    砂浆试样自修复前后的抗水渗透性

图(12)  /  表(3)
计量
  • 文章访问数:  142
  • HTML全文浏览量:  99
  • PDF下载量:  14
  • 被引次数: 6
出版历程
  • 收稿日期:  2024-04-22
  • 修回日期:  2024-06-05
  • 录用日期:  2024-06-13
  • 网络出版日期:  2024-06-28
  • 发布日期:  2024-06-26
  • 刊出日期:  2025-03-14

目录

/

返回文章
返回