Abstract:
To systematically investigate the compressive behavior of glass fiber-reinforced polymer (GFRP) spiral-confined concrete (GSCC) columns, 20 GSCC and plain concrete specimens were designed and tested under axial and eccentric compression, with GFRP spiral pitch and load eccentricity as the primary variables. The failure modes, load-carrying capacities, and deformation characteristics were comprehensively evaluated. The results demonstrate that GFRP spirals provide effective lateral confinement to the concrete core, substantially enhancing its compressive strength and deformation capacity. Under axial compression, GSCC specimens with a volumetric spiral reinforcement ratio of 4.06% exhibited an approximately 58.2% increase in peak load, and its ultimate deformation capacity reached 4.2 times that of the plain concrete counterpart. Under eccentric compression, the load-carrying capacity of GSCC specimens decreased markedly with increasing load eccentricity, accompanied by a progressive transition in failure mode from concrete crushing in the compression zone to brittle cracking in the tension zone. At an eccentricity ratio of 25.0%, the peak load of the G9-P30 series decreased by approximately 78.0% relative to the corresponding concentrically loaded specimens. Furthermore, an existing constitutive model was employed to predict the axial load–strain response and ultimate load-carrying capacity of GSCC columns, with its predictive accuracy assessed against the experimental results. These findings provide valuable basis for the mechanical analysis and structural design of FRP spiral-reinforced concrete columns.