基于CFRP自传感的受压结构智能监测研究与应用

王舒扬, 谢桂华, 轩元, 冒鹏飞, 伏纯宇, 苗永红

王舒扬, 谢桂华, 轩元, 等. 基于CFRP自传感的受压结构智能监测研究与应用[J]. 复合材料学报, 2025, 42(3): 1528-1537. DOI: 10.13801/j.cnki.fhclxb.20240701.004
引用本文: 王舒扬, 谢桂华, 轩元, 等. 基于CFRP自传感的受压结构智能监测研究与应用[J]. 复合材料学报, 2025, 42(3): 1528-1537. DOI: 10.13801/j.cnki.fhclxb.20240701.004
WANG Shuyang, XIE Guihua, XUAN Yuan, et al. Study and application of smart monitoring on compressed structures based on CFRP self-sensing[J]. Acta Materiae Compositae Sinica, 2025, 42(3): 1528-1537. DOI: 10.13801/j.cnki.fhclxb.20240701.004
Citation: WANG Shuyang, XIE Guihua, XUAN Yuan, et al. Study and application of smart monitoring on compressed structures based on CFRP self-sensing[J]. Acta Materiae Compositae Sinica, 2025, 42(3): 1528-1537. DOI: 10.13801/j.cnki.fhclxb.20240701.004

基于CFRP自传感的受压结构智能监测研究与应用

基金项目: 江苏大学第22批大学生科研课题立项资助项目(22A394)
详细信息
    通讯作者:

    谢桂华,博士,副教授,硕士生导师,研究方向为复合材料与复合结构 E-mail: xgh2007@ujs.edu.cn

  • 中图分类号: TU599;TB332

Study and application of smart monitoring on compressed structures based on CFRP self-sensing

Funds: The 22nd Batch of Undergraduate Research Projects Funded by Jiangsu University (22A394)
  • 摘要:

    本文探索了基于碳纤维增强聚合物基复合材料(CFRP)智能特性的受压构件健康监测新方法。将CFRP智能带以不同角度黏贴在轴向受压混凝土柱的侧面,研究准静态单调压缩和循环压缩作用下不同偏轴角的智能带的电阻响应特征。结果表明:CFRP智能带在单调加载全过程中的电阻与被监测结构的阶段化变化相关,经历了初期的缓慢变化、中期的快速变化和结构失效时的急剧变化,直至结构失效后电阻部分恢复;循环荷载作用下电阻呈周期性变化,且大部分电阻变化可以恢复,仅有少量不可恢复电阻产生于首次循环加载阶段。此外,偏轴角β对电阻响应具有重要影响:β=0°与90°时智能带分别呈现负压阻效应和正压阻效应,而45°偏轴角时智能带分阶段出现不同的压阻效应,且电阻变化幅度相对较小。工程应用实践结果验证了上述CFRP智能带在结构监测中的可行性和有效性。

     

    Abstract:

    A novel approach to structural health monitoring of compressed structures leveraging the intelligent properties of carbon fiber Reinforced Polymer (CFRP) was investigated. Smart CFRP strips were attached to the side surfaces of the axially compressed concrete column at various angles, and the electrical resistance of these strips under both monotonic and cyclic compression at different off-axial angles were analyzed. The findings reveal that the resistance of smart CFRP strips throughout the entire monotonic loading process correlates with the changes of the monitored structure, undergoing initial gradual changes, rapid changes at middle stage, and a sharp change upon the structural failure. The resistance changes partly reverse after failure. Under cyclic loading, the resistance shows periodic variations, with the resistance changes primarily being reversible, except for a small amount of irreversible resistance that occurs during the first loading cycle. Additionally, the off-axial angle, β, significantly influences the resistance response. At β=0° and β=90°, the smart strips exhibit negative and positive piezoresistive effects, respectively; while at β=45°, they display various piezoresistive effects in different phases, with a smaller change in resistance. The practical application results confirm the applicability and efficiency of the smart CFRP strips in structural monitoring.

     

  • 土木建筑结构因需承受各种结构性和环境性作用而导致服役能力逐年衰减,结构安全性下降。因此,为了确保结构可靠地工作,实时监测结构状态并为其潜在的风险提供早期预警是很有必要的。传统的损伤检测方法常会造成既有结构损伤,而无损检测技术如声发射法[1]、超声检测法[2]、射线检测法[3]、红外热成像法[4]等,大多存在操作程序复杂、精度受很多因素影响,且难以实现长期监测的缺点。近年来,众多学者基于分布式光纤传感技术,对桥梁钢拉索[5]、纤维增强聚合物基复合材料(FRP)加固混凝土构件[6-7]及结构[8-9]进行了结构健康监测的研究与实践。该法在结构长距离监测中具有灵敏度高、测量范围广、精度高等显著优势,但其复杂的安装过程及较高成本限制了其工程应用。

    另一方面,碳纤维增强聚合物基复合材料(CFRP)具有耐腐蚀、比强度高、抗疲劳性能好等性能优势,在工程结构尤其是加固结构中得以广泛应用[10-11]。同时,研究者发现,CFRP的电阻随应变变化[12-14],即具有正向或者负向的“压阻效应”[15]。故而,CFRP结构构件能根据自身的电信号变化,感知结构自身在静、动力荷载作用下产生的应变和变形,进而诊断出结构可能出现的弹性变形、断裂、疲劳损伤、分层和脱粘等损伤[16-18]。这种方法既不损伤原结构,也不需额外附加传感器和大型监测设备,施工简便,且可监测包括弹性阶段、裂纹萌生乃至损伤扩展全过程的结构状态。Fouad等[19]在役结构的FRP加固层中编入长标距碳纤维线性传感器,形成新型混杂纤维复合材料智能系统,可根据碳纤维上的电阻变化监测开裂荷载和FRP板与混凝土面层的初始脱粘。Feng和Ou[20] 通过集成压电陶瓷传感器与常用混凝土增强材料,提出了一种自感知碳纤维复合材料系统,以提高混凝土结构加固后的承载能力并监测裂缝萌生和发展。Abry等[21]和Weber等[22]通过测量电阻法监测CFRP板弯曲加载中的结构损伤。Goldfeld等[23]开展了系列基于碳纤维的织物增强混凝土梁的智能监测,研究了不同加载条件下电学和力学响应的关联性及结构自监测能力,分析了不同开裂程度下内部碳纤维束电学响应对水渗漏的敏感性[24]。Saleh等[25]和Han等[26]探索了不同偏轴角三维机织复合材料在拉伸和弯曲载荷下的电阻响应规律。石荣荣等[27]建立了三维编织复合材料碳纤维含量与电阻率的关系。薛有松等[28]通过准静态与疲劳试验探究了三维角联锁机织复合材料在弯曲下的力阻效应。

    迄今,相关研究仍很不全面,且主要集中在拉伸和弯曲加载中CFRP构件自身的智能特性方面,利用碳纤维智能特性对受压结构开展监测的相关研究鲜见报道。鉴于此,本文拟通过室内试验研究采用CFRP传感元件监测受压高延性混凝土柱实时状态的压阻特性,进而将之应用于某高延性混凝土加固砌体结构的施工期监测中,旨在为在役结构实现智能监测提供便利、有效的方法。

    采用C50高延性混凝土(HDC-120-II,西安五和新材料科技集团股份有限公司)制备混凝土柱(100 mm×100 mm×300 mm),标准养护28 d后模拟被监测结构构件;以课题组自主研发的1 mm厚树脂基预应力碳纤维智能带(含碳量65%,抗拉强度2244 MPa,极限伸长率1.8%)对混凝土柱在单轴压缩加载条件下的结构状态进行监测。

    为分析结构状态与CFRP智能带电响应的相互关系,在柱侧面中心处沿轴向布置电阻应变片各1个,同时在其附近沿不同角度β(竖向:β=0°、斜向:β=45°、水平:β=90°)各布置平行的CFRP智能带2个。智能带各组详情见表1

    表  1  碳纤维增强聚合物基复合材料(CFRP)智能带分组详情
    Table  1.  Details of smart carbon fiber reinforced polymer (CFRP) strips
    Group Number Dimension/mm3 Angle/(°)
    G1 G11 90×10×1 0
    G12 90×10×1 0
    G2 G21 90×10×1 45
    G22 90×10×1 45
    G3 G31 90×10×1 90
    G32 90×10×1 90
    下载: 导出CSV 
    | 显示表格

    采用电液伺服长柱压力试验机(济南鑫光试验机制造有限公司)进行准静态单轴压缩试验及循环加载试验,如图1所示。参考GB/T 50081—2019标准[29]对高延性混凝土柱预压数次后,进行单调压缩加载,试验中加载/卸载速率为±0.5 mm/min,循环加载的最大位移为2.9 mm。实时荷载及对应位移数据由试验机自动采集记录,CFRP智能传感带的实时电阻通过多路电阻测试仪(CXT2518-16,常州欣阳电子科技有限公司)采集,采集频率为0.5 Hz;应变测试结果由静态应变仪(uT7116Y,武汉优泰电子技术有限公司)采集,采集频率1 Hz。

    图  1  CFRP智能带布置与试件加载:(a)智能带布置图(单位:mm);(b)试件加载图
    Figure  1.  CFRP strips arrangement and specimen loading: (a) Strips layout (Unit: mm); (b) Specimen loading

    随着压缩荷载逐渐增大,延性混凝土柱从初始的弹塑性状态进入裂纹萌生与发展阶段,直至结构完全破坏,失效后CFRP智能带及所在基体的结构状态见图2。加载与卸载期间不同智能带的实时电阻Rt、电阻变化率ΔR/R以及混凝土柱中部的压缩应变ε图3。其中,智能带G12加载中部分剥离,故未能获得其全过程电阻变化,其他智能带的电阻变化率(ΔR/R)根据下式计算确定:

    图  2  柱失效后的智能带及所在混凝土基体状态
    Figure  2.  States of sensing strips and their substrate after column failure
    图  3  单调压缩作用下的全过程监测结果:(a) G11;(b) G12;(c) G21;(d) G22;(e) G31
    Figure  3.  Full-range monitoring results under monotonic compressive loading: (a) G11; (b) G12; (c) G21; (d) G22; (e) G31
    ε—Compressive strain of concrete columns; ∆R/R—Resistance change rate of CFRP smart strip; Rt—Real-time resistance of CFRP smart strip
    ΔRR=RtRR×100% (1)

    其中:R为CFRP智能带的初始电阻;Rt为加载中智能带的实时电阻;ΔR为电阻变化。

    图3可以看出,随混凝土柱状态的阶段性变化,全过程电阻按3个阶段呈现不同的变化趋势:(1)阶段I—弹塑性阶段。此阶段中混凝土柱处于弹塑性状态,轴向应变和横向应变随荷载逐渐增大;所有智能带的电阻在经历初始的不稳定变化后,保持较平缓的变化;(2)阶段II—损伤破坏阶段。混凝土中裂纹萌生并随荷载增大而扩展,直至裂纹贯通、结构完全失效;该阶段的智能带电阻变化明显增快;当荷载达到极限压缩荷载时,电阻出现急剧变化;(3)阶段III—失效后阶段。该阶段中荷载迅速减少到零,混凝土柱中的弹性变形随之恢复,但塑性变形和损伤不能恢复;与之相应的,CFRP智能带仍结构完好(除G12部分剥离外),电阻部分恢复,最终电阻相对变化较小。

    此外,对比第I、II阶段的电阻响应规律,可发现偏轴角β对智能带的压阻效应具有重要影响:G1(β=0°)的电阻和电阻变化率随应变增大出现明显下降,当结构失效时,G1对应的电阻和电阻变化出现突然反向大幅变化,即呈现典型的“负压阻效应”;相反,G3 (β=90°)的电阻随着应变增大而增大,直到结构失效时应变急剧下降,电阻和电阻变化率都随之迅速下降,体现了明显的“正压阻效应”; G2 (β=45°)的电阻随应变增大而下降,且下降速率不断增大;但结构失效时应变急速下降,而对应电阻和电阻变化率急剧减小,说明该智能带出现了由负压阻效应向正压阻效应的转变。以上差异体现了偏轴角对力阻效应的显著影响。尽管如此,这些智能带的电阻变化都与结构内部损伤具有较好的相关性,说明采用上述方法可有效地对结构的无损伤阶段、带损伤阶段和失效阶段等全过程进行监测。

    同时,对比3组CFRP智能带的电阻变化率可以看出,结构损伤在G1中引起的电阻相对变化远大于G3的电阻变化,说明正轴布置方式比偏轴布置方式对监测结构内部裂纹扩展和重要损伤更有效。

    周期性荷载作用下,结构应变呈现周期性变化,电阻也随之呈现显著的周期性变化规律,各智能带的实时电阻变化及混凝土柱在该处的同向应变如图4所示。

    图  4  循环荷载作用下的监测结果:(a) G11;(b) G12;(c) G21;(d) G22;(e) G31;(f) G32
    Figure  4.  Monitoring results under cyclic loading: (a) G11; (b) G12; (c) G21; (d) G22; (e) G31; (f) G32

    图4可知,智能带G1(β=0°)的电阻随着结构应变的增大而减小,随其减小而增大,呈现“负压阻效应”。这一现象与上文中单调缩中观察到的电阻变化结果一致,也与Todoroki等[30]在压缩单向板时观察到的“沿厚度方向和轴向的电阻同时下降”的规律相似,其原因主要是压缩导致了CFRP内部垂直于加载方向的碳纤维接触点增多,这一方面引起该方向的电阻下降,另一方面导致了CFRP材料内部缺陷周围的环绕电路增多,降低了沿纤维方向的电阻。

    与之不同的是,智能带G3组(β=90°)的电阻在整个载期间均呈现出与应变变化相同的趋势,即“正压阻效应”,且其电阻变化率小于G1组。这归因于两个方面的因素:一方面,混凝土基体上的轴向压应力会引起CFRP智能带的横向压缩,从而导致纤维横向接触增多,纤维方向与水平方向的电阻都随之下降;另一方面,泊松效应下,压缩荷载会引起混凝土基体向外膨胀,CFRP智能带内产生轴向拉应力,轴向电阻增大。这两方面对电阻产生相反的影响,实时电阻变化是这两者共同作用的结果。

    尽管45°方向的智能带(G2组)的初值电阻与其他两组电阻初值相当,但其在加载期间的电阻变化幅度却很小,这是由竖向方向与水平方向引起的不同电阻响应在该方向的叠加所导致的。不同偏轴角的CFRP 带的电学响应变化规律和幅值均不同,说明CFRP智能带的电学特性具有显著各向异性,该现象与众多学者对复合材料压阻效应各向异性的描述是一致的[12, 30]

    观察加载前后CFRP智能带的内部微观结构,可发现压缩加载会不同程度地改变CFRP智能带的微观结构,从而引起电阻变化。以G11为例(图5),循环加载后平行排列的碳纤维间距有所增大、且出现了纤维损伤和断裂现象,故而造成不可逆的电阻变化。对比多次循环中的电阻和内部结构可发现,不可逆电阻主要产生于首次加载中,在此后的数次加载中电阻变化几乎完全恢复。因此,总体上看,智能带具有良好的重复性。

    图  5  加载前后CFRP智能带的电镜扫描图:(a) 加载前;(b) 加载后
    Figure  5.  SEM images of CFRP strip before and after loading: (a) Before loading; (b) After loading

    需要说明的是,部分CFRP智能带的电阻变化相对于应变变化存在滞后现象。这与试验中的不同数据采集频率以及结构应变在界面上的传递效率有关:(1)电阻与应变由不同仪器采集,且两者固定的采集频率不同,故在数据处理中可能引起时差;(2)循环荷载下,混凝土柱与CFRP智能传感带之间的粘结界面上的微观损伤累计到一定程度时,会影响结构应变通过该界面传递到CFRP传感带的效率,从而导致电阻响应的滞后现象。

    而且,电阻滞后效应还可能受到CFRP传感带的微观结构变化的重要影响。CFRP的电阻变化主要受纤维和树脂基体的形变、纤维间的接触情况以及内部微观裂纹等因素的影响。在循环荷载下,CFRP内部不可逆的微观结构变化(如纤维断裂和裂纹扩展等)发生累积效应,导致这些不可逆的微观结构变化产生了时间效应,从而使被监测结构的应变变化曲线与CFRP传感带的电阻变化曲线出现时差。在文献[12]中(图6)也可以观察到这种滞后现象:前3次循环中电阻率响应和应力变化的一致性较好,但自第4个循环开始,电阻率开始出现了滞后。每个循环下的电阻率各不相同,这表明CFRP内部发生了不可逆的微观结构变化。因部分不可逆的微观结构变化需通过累积效应才会引起可测的电阻率变化,故电阻变化曲线随之出现滞后现象。

    图  6  环氧树脂基复合材料的接触电阻率和应力随时间的变化[12]
    Figure  6.  Variation of contact resistivity and stress with time for epoxy resin matrix composites[12]

    某四层砖混结构,原墙体均为部分风化的砖砌体结构,按照T/CECS 997—2022标准[31]采用高延性混凝土(HDC-120-II,西安五和新材料科技集团股份有限公司)对墙体进行双面加固。为监测施工过程及加固效果,按设计院建议取⑦轴上的横墙和C轴②~⑦之间的纵墙作为监测范围(图7),在两面墙的高延性混凝土嵌缝(水平向智能带)和混凝土外表面上(竖向智能带)布置监测点,如图8所示。

    图  7  底层墙体监测区域
    Figure  7.  Ground floor wall monitoring area
    XZGZ—New high ductility concrete-masonry composite structural column; BZJG—High ductility concrete jacketed reinforced wall column; WTJG—High ductility concrete jacketed reinforced window wall
    图  8  现场监测与分析
    Figure  8.  On-site monitoring and analysis

    以嵌缝监测点A1~A4和混凝土表面监测点B1~B4为例,绘制电阻变化率实时监测结果,见图9图10。由图9中可以看出,横墙嵌缝中CFRP智能带的电阻变化率曲线呈现了相似的变化趋势:延性混凝土结构层施工期,电阻经历了短暂的震荡后保持持续增长的趋势,施工完成后电阻趋于稳定。这说明随着施工推进,新黏附的延性混凝土逐渐增大的附加荷载被有效传递到了原墙体,从而引起了嵌缝内CFRP带的电阻在此期间不断增大;因加固层施工结束后无新的附加荷载产生,故电阻在结束后达到新的稳定阶段。

    图  9  嵌缝中CFRP带的电阻变化:(a)监测点A1(横墙);(b)监测点A2(横墙);(c)监测点A3(纵墙);(d)监测点A4(纵墙)
    Figure  9.  Fractional change in electrical resistance of CFRP strips in caulked joints: (a) Monitoring point A1 (transverse wall); (b) Monitoring point A2 (transverse wall); (c) Monitoring point A3 (longitudinal wall); (d) Monitoring point A4 (longitudinal wall)
    图  10  延性混凝土表面CFRP带的电阻变化:(a)监测点B1(横墙);(b)监测点B2(横墙);(c)监测点B3(纵墙);(d)监测点B4(纵墙)
    Figure  10.  Fractional change in electrical resistance of CFRP strips on concrete substrate: (a) Monitoring point B1 (transverse wall); (b) Monitoring point B2 (transverse wall); (c) Monitoring point B3 (longitudinal wall); (d) Monitoring point B4 (longitudinal wall)

    图10反映了黏贴于延性混凝土加固层表面的CFRP带的电阻在装饰层施工前后的变化。可以看出,在装饰层施工前,电阻基本稳定;随着横墙和纵墙上先后涂装装饰层,新的附加荷载先后引起了两面墙上的CFRP带的荷载变化,电阻在此期间不断增长;装饰层施工完成后,电阻变化率又趋于稳定,未见急剧或者大幅度变化,意味着新形成的复合结构进入稳定状态。

    本文研究采用碳纤维增强聚合物基复合材料(CFRP)智能带实现结构健康监测的新方法,以高延性混凝土柱模拟结构构件,对其进行准静态压缩和循环加载试验,分析不同黏贴方式下CFRP智能带的电学响应规律,通过工程实践检验本文方法的工程适用性。主要结论如下:

    (1) CFRP智能带的电阻随结构状态的不同呈现阶段性变化规律。当轴压构件处于弹塑性状态时,CFRP智能带的电阻经历短期的不稳定震荡后,趋于较稳定变化;随着结构构件中损伤产生和扩展,电阻变化也相应加快,直至构件失效时实时电阻对应地出现突变;

    (2)偏轴角β对智能带的压阻效应具有重要影响。β=0°时智能带表现为负压阻效应,β=90°时智能带表现为正压阻效应,而β=45°时,智能带在不同阶段具有不同的压阻效应,且电阻变化率相对较小。这意味着采用CFRP智能带对受压结构进行实时监测时,采用β=0°的布置方式比沿其他布置方式具有更高的敏感性;

    (3)尽管循环作用会引起CFRP智能带的微观结构变化,但其不可恢复电阻主要产生于首次循环加载中,整个循环加载过程中的电阻变化大部分可以恢复,从而使CFRP带具有较好的重复性;

    (4)工程实践结果验证了本文提出的以β=0°和β=90°的智能带进行结构实时监测的可行性和有效性。

  • 图  1   CFRP智能带布置与试件加载:(a)智能带布置图(单位:mm);(b)试件加载图

    Figure  1.   CFRP strips arrangement and specimen loading: (a) Strips layout (Unit: mm); (b) Specimen loading

    图  2   柱失效后的智能带及所在混凝土基体状态

    Figure  2.   States of sensing strips and their substrate after column failure

    图  3   单调压缩作用下的全过程监测结果:(a) G11;(b) G12;(c) G21;(d) G22;(e) G31

    Figure  3.   Full-range monitoring results under monotonic compressive loading: (a) G11; (b) G12; (c) G21; (d) G22; (e) G31

    ε—Compressive strain of concrete columns; ∆R/R—Resistance change rate of CFRP smart strip; Rt—Real-time resistance of CFRP smart strip

    图  4   循环荷载作用下的监测结果:(a) G11;(b) G12;(c) G21;(d) G22;(e) G31;(f) G32

    Figure  4.   Monitoring results under cyclic loading: (a) G11; (b) G12; (c) G21; (d) G22; (e) G31; (f) G32

    图  5   加载前后CFRP智能带的电镜扫描图:(a) 加载前;(b) 加载后

    Figure  5.   SEM images of CFRP strip before and after loading: (a) Before loading; (b) After loading

    图  6   环氧树脂基复合材料的接触电阻率和应力随时间的变化[12]

    Figure  6.   Variation of contact resistivity and stress with time for epoxy resin matrix composites[12]

    图  7   底层墙体监测区域

    Figure  7.   Ground floor wall monitoring area

    XZGZ—New high ductility concrete-masonry composite structural column; BZJG—High ductility concrete jacketed reinforced wall column; WTJG—High ductility concrete jacketed reinforced window wall

    图  8   现场监测与分析

    Figure  8.   On-site monitoring and analysis

    图  9   嵌缝中CFRP带的电阻变化:(a)监测点A1(横墙);(b)监测点A2(横墙);(c)监测点A3(纵墙);(d)监测点A4(纵墙)

    Figure  9.   Fractional change in electrical resistance of CFRP strips in caulked joints: (a) Monitoring point A1 (transverse wall); (b) Monitoring point A2 (transverse wall); (c) Monitoring point A3 (longitudinal wall); (d) Monitoring point A4 (longitudinal wall)

    图  10   延性混凝土表面CFRP带的电阻变化:(a)监测点B1(横墙);(b)监测点B2(横墙);(c)监测点B3(纵墙);(d)监测点B4(纵墙)

    Figure  10.   Fractional change in electrical resistance of CFRP strips on concrete substrate: (a) Monitoring point B1 (transverse wall); (b) Monitoring point B2 (transverse wall); (c) Monitoring point B3 (longitudinal wall); (d) Monitoring point B4 (longitudinal wall)

    表  1   碳纤维增强聚合物基复合材料(CFRP)智能带分组详情

    Table  1   Details of smart carbon fiber reinforced polymer (CFRP) strips

    Group Number Dimension/mm3 Angle/(°)
    G1 G11 90×10×1 0
    G12 90×10×1 0
    G2 G21 90×10×1 45
    G22 90×10×1 45
    G3 G31 90×10×1 90
    G32 90×10×1 90
    下载: 导出CSV
  • [1]

    ZHOU W, ZHAO W, ZHANG Y, et al. Cluster analysis of acoustic emission signals and deformation measurement for delaminated glass fiber epoxy composites[J]. Composite Structures, 2018, 195: 349-358. DOI: 10.1016/j.compstruct.2018.04.081

    [2]

    SMITH R A, NELSON L J, MIENCZAKOWSKI M J, et al. Ultrasonic analytic-signal responses from polymer-matrix composite laminates[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2017, 65(2): 231-243.

    [3]

    BULL D J, HELFEN L, SINCLAIR I, et al. A comparison of multi-scale 3D X-ray tomographic inspection techniques for assessing carbon fibre composite impact damage[J]. Composites Science and Technology, 2013, 75: 55-61. DOI: 10.1016/j.compscitech.2012.12.006

    [4]

    FERNANDES H, ZHANG H, FIGUEIREDO A, et al. Carbon fiber composites inspection and defect characterization using active infrared thermography: Numerical simulations and experimental results[J]. Applied Optics, 2016, 55(34): D46-D53. DOI: 10.1364/AO.55.000D46

    [5] 周智, 何建平, 贾宏伟, 等. 平行钢丝束拉索的布里渊全尺度测试技术研究[J]. 光电子. 激光, 2009, 20(6): 766-770.

    ZHOU Zhi, HE Jianping, JIA Hongwei, et al. Full scale brillouin sensing technique based smart parallel wire stay cable[J]. Journal of Optoelectronics·Laser, 2009, 20(6): 766-770(in Chinese).

    [6]

    TANG Y, YAO Y, CANG J. Structural and sensing performance of RC beams strengthened with prestressed near-surface mounted self-sensing basalt FRP bar[J]. Composite Structures, 2021, 259: 113474. DOI: 10.1016/j.compstruct.2020.113474

    [7] 邓朗妮, 谢宏, 刘阳, 等. CFRP-OFBG板嵌入式加固钢筋混凝土梁荷载效应计算分析[J]. 复合材料科学与工程, 2020(3): 5-10. DOI: 10.3969/j.issn.1003-0999.2020.03.001

    DENG Langni, XIE Hong, LIU Yang, et al. Load effect calculation and analysis of CFRP-OFBG plate embedded reinforced concrete beam[J]. Composites Science and Engineering, 2020(3): 5-10(in Chinese). DOI: 10.3969/j.issn.1003-0999.2020.03.001

    [8]

    ZHAO M M, DONG Y T, ZHAO Y, et al. Monitoring of bond in FRP retrofitted concrete structures[J]. Journal of Intelligent Material Systems and Structures, 2007, 18(8): 853-860. DOI: 10.1177/1045389X06074571

    [9]

    TANG Y, WANG Z, SONG M. Self-sensing and strengthening effects of reinforced concrete structures with near-surfaced mounted smart basalt fibre–reinforced polymer bars[J]. Advances in Mechanical Engineering, 2016, 8(10): 1-19.

    [10] 张智梅, 杨旸. 外贴预应力CFRP布加固钢筋混凝土梁抗弯疲劳性能有限元分析[J]. 复合材料科学与工程, 2023(2): 44-53.

    ZHANG Zhimei, YANG Yang. Finite element analysis of the flexural fatigue performance of reinforced conerete beams reinforced with externally bonded prestressed CFRP sheets[J]. Composites Science and Engineering, 2023(2): 44-53(in Chinese).

    [11] 宋岩超, 蒋济同. 新型封闭式复丝缠绕CFRP箍筋抗拉强度正交试验研究[J]. 复合材料科学与工程, 2024(11): 82-87.

    SONG Yanchao, JIANG Jitong. Orthogonal test of a new type of closed compound filament wound CFRP stirrup [J]. Composites Science and Engineering, 2024(11): 82-87(in Chinese).

    [12]

    CHUNG D D L. A review to elucidate the multi-faceted science of the electrical- resistance-based strain/temperature/damage self-sensing in continuous carbon fiber polymer-matrix structural composites[J]. Journal of Materials Science, 2023, 58(2): 483-526. DOI: 10.1007/s10853-022-08106-7

    [13]

    SCHULTE K, BARON C. Load and failure analyses of CFRP laminates by means of electrical resistivity measurements[J]. Composites Science and Technology, 1989, 36(1): 63-76. DOI: 10.1016/0266-3538(89)90016-X

    [14] 吴智深, 张建. 结构健康监测先进技术及理论[M]. 北京: 科学出版社, 2018: 119-122.

    WU Zhishen, ZHANG Jian. Advanced structural health monitoring technology and theory[M]. Beijing: Science Press, 2018: 119-122(in Chinese).

    [15]

    LEE I Y, ROH H D, PARK Y B. Novel structural health monitoring method for CFRPs using electrical resistance based probabilistic sensing cloud[J]. Composites Science and Technology, 2021, 213: 108812. DOI: 10.1016/j.compscitech.2021.108812

    [16] 薛伟辰, 谭园. 土木工程自监测纤维复合材料[J]. 玻璃钢/复合材料, 2007(5): 53-56.

    XUE Weichen, TAN Yuan. Fiber reinforced polymers with self-monitoring properties used in civil engineering[J]. Composites Science and Engineering, 2007(5): 53-56(in Chinese).

    [17] 张小玉, 朱四荣, 李卓球. 碳纤维智能带电阻率层析成像实验[J]. 华中科技大学学报: 自然科学版, 2010, 38(5): 121-123.

    ZHANG Xiaoyu, ZHU Sirong, LI Zhuoqiu. Electrical resistance tomography experiment of carbon fiber smart layers[J]. Jouinal of Huazhong University of Science and Technology (Natural Science Edition), 2010, 38(5): 121-123(in Chinese).

    [18]

    HUANG H, YANG C, WU Z. Electrical sensing properties of carbon fiber reinforced plastic strips for detecting low-level strains[J]. Smart Materials and Structures, 2012, 21(3): 035013. DOI: 10.1088/0964-1726/21/3/035013

    [19]

    FOUAD N, SAIFELDEEN M A. Smart self-sensing fiber-reinforced polymer sheet with woven carbon fiber line sensor for structural health monitoring[J]. Advances in Structural Engineering, 2021, 24(1): 17-24. DOI: 10.1177/1369433220944507

    [20]

    FENG Q, OU J. Self-sensing CFRP fabric for structural strengthening and damage detection of reinforced concrete structures[J]. Sensors, 2018, 18(12): 4137. DOI: 10.3390/s18124137

    [21]

    ABRY J C, BOCHARD S, CHATEAUMINOIS A, et al. In situ detection of damage in CFRP laminates by electrical resistance measurements[J]. Composites Science and Technology, 1999, 59(6): 925-935. DOI: 10.1016/S0266-3538(98)00132-8

    [22]

    WEBER I, SCHWARTZ P. Monitoring bending fatigue in carbon-fibre/epoxy composite strands: A comparison between mechanical and resistance techniques[J]. Composites Science and Technology, 2001, 61(6): 849-853. DOI: 10.1016/S0266-3538(01)00028-8

    [23]

    GOLDFELD Y, YOSEF L. Electrical-structural characterisation of smart carbon-based textile reinforced concrete beams by integrative gauge factors[J]. Strain, 2020, 56(4): e12344. DOI: 10.1111/str.12344

    [24]

    GOLDFELD Y, BEN-AAROSH S, RABINOVITCH O, et al. Integrated self-monitoring of carbon based textile reinforced concrete beams under repeated loading in the uncracked region[J]. Carbon, 2016, 98: 238-249. DOI: 10.1016/j.carbon.2015.10.056

    [25]

    SALEH M N, YUDHANTO A, LUBINEAU G, et al. The effect of z-binding yarns on the electrical properties of 3D woven composites[J]. Composite Structures, 2017, 182: 606-616. DOI: 10.1016/j.compstruct.2017.09.081

    [26]

    HAN C, HUANG S, SUN B, et al. Electrical resistance changes of 3D carbon fiber/epoxy woven composites under short beam shear loading along different orientations[J]. Composite Structures, 2021, 276: 114549. DOI: 10.1016/j.compstruct.2021.114549

    [27] 石荣荣, 武宝林. 三维编织碳纤维复合材料电阻率的估算[J]. 复合材料学报, 2016, 33(12): 2775-2780.

    SHI Rongrong, WU Baolin. Resistivity estimation of 3D braided carbon fiber composites[J]. Acta Materiae Compositae Sinica, 2016, 33(12): 2775-2780(in Chinese).

    [28] 薛有松, 薛凌明, 孙宝忠, 等. 碳纤维三维角联锁机织复合材料弯曲作用下力阻响应[J]. 复合材料学报, 2023, 40(3): 1468-1476.

    XUE Yousong, XUE Lingming, SUN Baozhong, et al. Piezoresistive effect of carbon fiber 3D angle-interlock woven composites under bending[J]. Acta Materiae Compositae Sinica, 2023, 40(3): 1468-1476(in Chinese).

    [29] 中华人民共和国住房和城乡建设部. 混凝土物理力学性能试验方法标准: GB/T 50081—2019[S]. 北京: 中国建筑工业出版社, 2019.

    Ministry of Housing and Urban-Rural Development of the People's Republic of China. Standard for test methods of concrete physical and mechanical properties: GB/T 50081—2019[S]. Beijing: China Architecture & Building Press, 2019(in Chinese).

    [30]

    TODOROKI A, TANAKA M, SHIMAMURA Y. Measurement of orthotropic electric conductance of CFRP laminates and analysis of the effect on delamination monitoring with an electric resistance change method[J]. Composites Science and Technology, 2002, 62(5): 619-628. DOI: 10.1016/S0266-3538(02)00019-2

    [31] 西安建筑科技大学. 高韧性混凝土加固砌体结构技术规程: T/CECS 997—2022[S]. 北京: 中国建筑工业出版社, 2022.

    Xi'an University of Architecture and Technology. Technical specification for strengthening masonry structure with toughness-concrete: T/CECS 997—2022[S]. Beijing: China Architecture & Building Press, 2022(in Chinese).

  • 其他相关附件

  • 目的 

    随着科学技术的进步,SHM(结构健康监测)成为确保结构安全性和可靠性的重要手段。然而,传统的损伤监测方法存在对结构损伤及复杂、精度受限等问题,亟需一种便捷且有效的长期监测方法。CFRP(碳纤维增强聚合物基复合材料)因其压阻效应在结构健康监测中展示出巨大潜力。本文通过轴向压缩试验研究不同偏轴角的CFRP智能带对混凝土柱应变及损伤的感知能力,以期得到基于CFRP智能特性的新型受压结构健康监测方法。

    方法 

    制备了不同偏轴角(0°、45°、90°)的CFRP智能带,并将其黏贴在轴向受压混凝土柱的侧面,进行准静态单调压缩和循环压缩试验。通过万能试验机进行加载,记录加载过程中CFRP智能带的电阻变化及混凝土柱的应变。采用多路电阻测试仪和静态应变仪分别采集实时电阻和应变数据。通过分析CFRP智能带在不同加载条件下的电阻响应特征,探讨其与结构状态的相关性及预警效果。

    结果 

    研究结果表明,CFRP智能带在单调压缩加载过程中,电阻变化与结构的阶段性变化密切相关。加载初期,电阻缓慢变化;中期,电阻加速变化;结构失效时,电阻急剧变化。循环压缩加载下,电阻呈现周期性变化,大部分电阻变化可恢复,仅有少量不可逆电阻变化发生在首次循环中。此外,偏轴角对电阻响应具有显著影响:偏轴角0°时,智能带表现出负压阻效应;偏轴角90°时,表现出正压阻效应;偏轴角45°时,电阻变化幅度相对较小但复杂。工程应用验证了基于CFRP智能带的监测方法在受压结构健康监测中的可行性和有效性。

    结论 

    本文提出了一种基于CFRP智能特性的受压结构健康监测新方法,通过准静态和循环压缩试验,分析了不同偏轴角CFRP智能带的电阻响应规律。研究表明,CFRP智能带能够有效监测结构状态的阶段性变化,具有较好的重复性和预警能力。偏轴角对智能带的压阻效应影响显著,采用偏轴角0°的布置方式监测敏感性更高。工程应用结果验证了本文方法在结构健康监测中的实用性,为在役结构实现智能监测提供了一种便捷、有效的途径。

  • 传统的损伤检测方法常会造成既有结构损伤,而无损检测技术大多存在操作程序复杂、精度受很多因素影响的问题,故亟需一种更便捷的长期监测方法。CFRP(碳纤维增强聚合物基复合材料)因具有压阻效应在结构健康监测中具有巨大的潜力,然而已有成果主要集中在CFRP材料自身的智能特性方面,且以弯曲和拉伸试验研究为主,受压构件的智能监测研究鲜见。

    本文研究了利用CFRP智能特性进行受压结构构件健康监测的新方法。通过室内准静态压缩和循环压缩试验,分析了采用不同偏轴角的CFRP智能带对轴压混凝土柱的监测性能,发现偏轴角0°时的压阻效应优于偏轴角45°和90°;根据单调和循环压缩荷载作用下的结构应变与电阻响应规律,研究了CFRP智能带的实时电阻与结构状态的相关性,以及电阻变化对结构损伤的预警性;通过循环加载中的电阻变化分析,发现CFRP智能带的压阻行为具有较好的重复性,不可逆电阻变化主要发生在首次循环中;最后通过实际工程应用验证了本文方法在受压结构构件智能监测中的可行性和有效性。

    CFRP智能带的电阻变化曲线: (a) 单轴压缩至失效;(b) 循环压缩

    Resistance change of CFRP smart strip: (a) under axial compression to failure; (b) under cyclic compression

图(10)  /  表(1)
计量
  • 文章访问数:  165
  • HTML全文浏览量:  90
  • PDF下载量:  10
  • 被引次数: 0
出版历程
  • 收稿日期:  2024-04-08
  • 修回日期:  2024-06-13
  • 录用日期:  2024-06-23
  • 网络出版日期:  2024-07-04
  • 发布日期:  2024-07-02
  • 刊出日期:  2025-03-14