Abstract:
Degradable material is an important part of biomaterials, its degradation performance
in vivo has great influence on the final success after implantation. Thus, the method of evaluating the degradation of the materials
in vivo is crucial to the evaluation of material performance. The traditional method to estimate the degradation
in vivo needs to take out different batches of degradation samples at each sampling point, which prevents the continuous measurement of the degradation process and it needs a large number of samples.
In vivo imaging system (IVIS) has the characteristics of non-invasive and strong operability, which provides a way to solve the problems above. In this study, we established a method to detect the degradation performance of degradable materials with IVIS. The research method was that the near-infrared fluorescent dye was labeled on the degradable materials by chemical reaction, and then using the change of fluorescence intensity to reflect the degradation degree of the materials. The
in vivo degradation experimental results show that the fluorescent labeling materials prepared by this method have high fluorescence stability, and the fitting effect of fluorescence intensity and mass loss in the process of material degradation is good (
R2 = 0.9994). In conclusion, this method solves the problem of large amount of samples in the traditional method of measuring material degradation, and improves the continuity of the experimental process.