Tensile behavior and parameters designing of double-sides flush repair of composite laminates
-
摘要: 对含穿透型损伤层压板双面挖补胶接修补件的拉伸性能及主要影响参数进行了试验研究。结果表明: 双面挖补后的失效拉伸强度恢复率能够达到80%; 当挖补斜度1∶40、 覆盖层取3层、 且靠近母板的铺层方向与母板的最外层的铺层方向保持一致时, 强度恢复率较大; 使用双面挖补后, 母板厚度、 母板铺层方式对强度恢复率的影响不大。同时应用有限元软件ABAQUS, 采用三维实体单层设置建模方式对双面挖补层压板的拉伸性能进行了数值模拟, 模拟计算结果与试验结果基本相符。Abstract: The tensile behavior of composite laminate containing penetrated damage and the optimization of repair designing parameters were studied after being flush repaired on double-sides. The results demonstrate that the recovery of failure strength of repairing specimens could reach 80% after double-sided flush repaired. The strength of repair specimens can be recovered to the maximum, when scarf ratio is 1∶40, and covering layers number is three with the layer's orientation is the same as the mother plate's layer which is close to covering layers. Double-sides flush repairing is familiar to any thicknesses and any lay-up ways of the mother laminates. A 3D finite element analysis was studied to verify the test result using ABAQUS software. In the model, every layer was set as a section, then give it the orientation of each layer. The analysis data are agree with the test results.