Abstract:
Ceramic matrix composite (CMC) have emerged as a promising structural material for modern aerospace high-temperature applications, owing to their exceptional specific strength, specific stiffness, thermal stability, and low density. The positioning, assembly and connection structure design and performance verification of CMC and traditional high-temperature alloy components are the key to realizing the engineering application of CMC. This study developed a series of CMC–metal positioning connection structures based on laminated SiC fiber-reinforced SiC (SiC
f/SiC) composites fabricated via the melt infiltration (MI) process. Extrusion quasi-static failure and extrusion fatigue tests were conducted at 900 ℃, complemented by in-situ, real-time quantitative characterization using digital image correlation to capture localized deformation evolution and damage progression within the connection interface. Results indicate that, at 900 ℃, the GH3536 superalloy exhibits markedly reduced stiffness and strength relative to the SiC
f/SiC composite; consequently, the metallic protrusion undergoes substantial plastic deformation and eventual structural collapse under extrusion loading. In contrast, the CMC component displays limited, superficial damage—including surface delamination, isolated microcracking, and minor corner chipping—without catastrophic failure. Crucially, the contact depth between the CMC and metal components exerts a pronounced influence on both the extrusion mechanical response and the dominant damage mode: for the simulated specimen A, when the contact length b in the thickness direction of the CMC is large (b ≥ 1.83mm), the metal protrusion undergoes plastic deformation to a certain extent, and the metal protrusion and the CMC suddenly experience a slight sliding/displacement, resulting in a sudden change in displacement and load; when the contact length b in the thickness direction of the CMC is small (b ≤ 1.51mm), the plastic deformation of the metal protrusion gradually increases, and local cracking/fatigue cracking of the CMC gradually occurs, and the extrusion load stabilizes or gradually decreases. Although the GH3536 protrusion fails completely in both failure and fatigue regimes, appropriately tailored connection geometry enables retention of functional positioning capability throughout testing.