Abstract:
To systematically reveal the influence of the ultra-high performance concrete (UHPC) layer thickness on the flexural performance of UHPC–normal concrete (NC) composite beams under salt freeze-thaw conditions, and to develop a load-bearing capacity degradation model that accounts for salt freeze–thaw damage, this study presents an experimental and theoretical investigation. A total of 12 composite beams with six different UHPC layer thicknesses were subjected to 90 salt freeze-thaw cycles, followed by four-point bending tests. The mechanisms through which the UHPC layer thickness affects the macro-mechanical response and micro-damage evolution were explored via microstructural analysis. The results indicate that the dense microstructure of the UHPC layer effectively impedes chloride ingress and freeze-thaw damage. A thickness equivalent to 1/6 of the beam height was found to provide sufficient durability protection. Mechanically, relative to the NC control beams without a UHPC layer, the specimens with a 25 mm UHPC layer showed increases of 105% in cracking load and 47% in ultimate load capacity. A bearing capacity model coupling material degradation and section damage was established, and its predictions showed good agreement with experimental results, with a maximum error of 9.7%. This work provides a theoretical basis for the design of such composite structures in harsh environments.