XU Ying, CHAI Lei, LU Miaomiao. Failure mechanism of FRP reinforced concrete column with initial defects[J]. Acta Materiae Compositae Sinica, 2017, 34(8): 1712-1720. doi: 10.13801/j.cnki.fhclxb.20161116.001
Citation: XU Ying, CHAI Lei, LU Miaomiao. Failure mechanism of FRP reinforced concrete column with initial defects[J]. Acta Materiae Compositae Sinica, 2017, 34(8): 1712-1720. doi: 10.13801/j.cnki.fhclxb.20161116.001

Failure mechanism of FRP reinforced concrete column with initial defects

doi: 10.13801/j.cnki.fhclxb.20161116.001
  • Received Date: 2016-09-05
  • Rev Recd Date: 2016-10-17
  • Publish Date: 2017-08-15
  • The effect of initial defect size on the mechanical behavior and failure pattern of CFRP (Carbon Fiber Reinforced Polymer)-confined concrete columns was investigated through theoretical analysis, numerical simulation and experiment validation. Qualitative theoretical analysis was firstly explored to study the effect of initial defect size on the integrity of FRP-confined concrete from macro to micro perspective. Numerical analysis and experimental investigation were then carried out and compared to investigate the failure mechanism of FRP-confined concrete column with initial defects under axial compression force and eccentric compression force. The variation of defect criticality was investigated by varying the layer number of CFRP and cross-section size of concrete columns. The effect of initial defect size on the failure mechanism of CFRP-confined concrete columns was finally demonstrated.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (625) PDF downloads(597) Cited by()